31
5.4. CTC-1052 Programming Command Table
DTMF
CHARACTER
COMMANDS
DTMF
ACK
COMMAND OPERATION
TERM
I-
NATO
R
DTMF
ACK
DEFAULT
01# Bi Telephone number 1 # Bi No number
02# Bi Telephone number 2 # Bi No number
03# Bi Telephone number 3 # Bi No number
04# Bi Telephone number 4 # Bi No number
05# Bi
Telephone number & GPRS/IP for alarm report
1=TEL1 , 2=TEL2 , 3=TEL3 , 4=TEL4,
5=GPRS1 , 6=GPRS2
# Bi 1,2,3,4,5,6
06# Bi
Telephone number& GPRS/IP for status report
1=TEL1 , 2=TEL2 , 3=TEL3 , 4=TEL4,
5=GPRS1 , 6=GPRS2
# Bi 1,2,3,4,5,6
07# Bi
Select Telephone number for Non-Emergency Call
0= Disable, 1=TEL1 , 2=TEL2 , 3=TEL3 , 4=TEL4
# Bi Disable
10# Bi Global account number, 4 to 6 digits # Bi No account number
11# Bi 4-6 digits Account number 1 (Tel. Number 1) # Bi No account number
12# Bi 4-6 digits Account number 2 (Tel. Number 2) # Bi No account number
13# Bi 4-6 digits Account number 3 (Tel. Number 3) # Bi No account number
14# Bi 4-6 digits Account number 4 (Tel. Number 4) # Bi No account number
20# Bi
All formats the same, 0 = Contact ID,
1= Scancom, 2 = Tunstall, 3 = Speech, 4=SMS CID
# Bi Contact ID
21# Bi
0 = Contact ID, 1= Scancom, 2 = Tunstall,
3 = Speech, 4=SMS CID (Tel. Number 1)
# Bi Contact ID
22# Bi
0 = Contact ID, 1= Scancom, 2 = Tunstall,
3 = Speech, 4=SMS CID (Tel. Number 2)
# Bi Contact ID
23# Bi
0 = Contact ID, 1= Scancom, 2 = Tunstall,
3 = Speech, 4=SMS CID (Tel. Number 3)
# Bi Contact ID
24# Bi
0 = Contact ID, 1= Scancom, 2 = Tunstall,
3 = Speech, 4=SMS CID (Tel. Number 4)
# Bi Contact ID
31# Bi Ringer enable, 0 = Disable, 1 = Enable # Bi Ringer Disabled
32# Bi Audible fault alert, 0 = Off, 1 = On # Bi Off
33# Bi Help arrived signalling, 0 = Off, 1 = On # Bi
Help arrived
signalling Off
34# Bi
Emergency button enable, 0 = Button off, 1 =Button
on
# Bi
Emergency button
On
35# Bi Silent Mode, 0 = Silent mode On, 1 = Silent mode Off # Bi Silent mode Off
37# Bi AC fault report, 0 = Off, 1 = On # Bi On
38# Bi
Follow-On & Call Back Function, 0 = Follow-On, 1=
Call-Back, 2= Follow-On & Call-Back
# Bi Follow-On
40# Bi Set Access Code # Bi 1111
42# Bi
Guard time delay for any compatible sensor (except
Fall Sensor), 00 = Instant reporting; … 99 = 99 seconds
# Bi 10 seconds
43# Bi
Test call, 0 = OFF, 1 = 1 Day, 2 = 2 Days,
3 = 3 Days, 4 = 4 Days. 5 = 5 Days,
6 = 6 Days, 7 = 7 Days, 8 = 30 days
# Bi No test call

Related product manuals