32
DTMF
CHARACTER
COMMANDS
DTMF
ACK
COMMAND OPERATION
TERMI-
NATOR
DTMF
ACK
DEFAULT
44# Bi
Mobility time
00= Disable, 01 ~ 36= 1 ~ 36 Hours
# Bi
Mobility time
disable
45# Bi
Follow-On Choice, 0 = Wait command,
1 = Listen, 2 = Two way voice communication
# Bi
Two-way voice
communication
46# Bi
Follow-On mode & Two-Way Period,
01=1 min, 02=2mins, 03=3mins, 04=4mins,
05=5mins, 06=6mins, 07=7mins, 08=8mins,
09=9mins, 10=10mins.
# Bi 5 minutes
47# Bi
Off-set time, 1=1 hour, 2=2 hours, 3=3 hours,
4=4 hours, 5=8hours, 6=12 hours
# Bi 1 Hour
49# Bi
Supervision, 0 = disable, 1 = 4 days, 2 = 5 days, 3 =
6 days,4 = 7 days, 5 = 8 days, 6 = 9 days, 7 = 10 days
# Bi Disable
61# Bi
Check SIM CARD PIN CODE
0: Disable
1: Enable
# Bi Disable
62# Bi Set Input SIM CARD PIN CODE : 4 ~ 8 digital # Bi Null
63# Bi
Set Speaker Volume
Enter: Mode Number + + Speaker Volume
Note: Mode Number: 1 digit (2:Two-way)
Speak volume: 1 digit (1~5 level)
# Bi Two way mode: 3
64# Bi
Set Microphone Sensitivity:
Note: Mic sensitivity: 1 digit (1~5 level)
Only can be adjusted in the two-way mode.
# Bi Two way Mode: 3
66# Bi
Guard time delay for Fall Sensor, 00 = Instant
reporting; … 99 = 99 seconds
# Bi 15 sec
80# Bi Remove all device (learnt in Command 91-94) --- --- ---
81# Bi Remove pendant #1 (learnt in Command 91) --- --- ---
82# Bi Remove pendant #2 (learnt in Command 92) --- --- ---
83# Bi
Remove Silent Pendant
(learnt in Command 93)
--- --- ---
84# Bi Remove the Devices (learnt in Command 94) --- --- ---
91# Bi Learn-in pendant #1 --- Bi Bi No device
92# Bi Learn-in pendant #2 --- Bi Bi No device
93# Bi Learn-in silent emergency transmitters --- Bi Bi No device
94# Bi
Learn-in smoke detectors, CO detectors,
pendants and fixed emergency transmitters, long
range pendants
--- Bi Bi No device
98# Bi
Load defaults when ** is pressed (DTMF A is
heard after defaults have been loaded)
# Bi ---
99# Bi Exit programming mode ---