Basic electrical safety precautions for charging electric vehicles, avoiding hazards.
Turn off power at the circuit breaker before servicing or cleaning the unit.
Consult vehicle manual for indoor charging ventilation needs.
Do not charge vehicles indoors if they require ventilation.
Unauthorized modifications may void FCC compliance.
Overview of the LCS charging station for PEVs, hardwired and plug-in versions.
Details the meaning of indicator lights on the LCS front panel.
Connect only to circuits with appropriate overcurrent protection per NEC/CEC.
Do not connect all three phases of a 3-phase feed; use only two phases.
Phases must measure 120V to Neutral; Earth Ground to Neutral at one point.
For Delta 3-phase, use center-tapped leg, 120V to Neutral phases only.
Improper wiring will void the product warranty.
Installation must be performed by a qualified electrician per local codes.
Diagram showing 220/240V single-phase service transformer secondary connection.
Diagram showing 208V 3-phase Wye-connected service transformer secondary.
For 208V Wye, use any two legs; ensure center point is Earth Ground.
Diagram showing 240V 3-phase Delta-connected service transformer with center-tap.
For Delta connection, use center-tapped leg, 120V to Neutral phases only.
Delta secondary without center-tap is not usable; LCS needs Ground-fault protection.
Details on positioning the LCS unit for hardwired and plug-in models.
Always turn off power at the breaker before wiring or unplugging the unit.
Guidance for mounting the LCS unit to hollow walls using appropriate hardware.
Guidance for mounting the LCS unit to concrete, brick, or stone walls.
Describes the purpose and placement of the connector holster for safe access.
Recommended mounting heights for the connector holster indoors and outdoors.
Mount holster to ensure mounting holes align with solid structural framing.
Instructions for routing conduit and making connections to the service panel.
Read Service Connections on page 10 and consult utility if unsure of power.
Describes the color coding for LCS service conductors for 240VAC installations.
Lists available NEMA plug types for the LCS-P model.
LCS-P must be mounted below the receptacle and within 12 inches.
Illustrates preferred orientation of NEMA receptacles for LCS-P mounting.
Guidelines for wrapping the charge cable loosely to prevent overheating.
Grounding requirements for hardwired LCS units.
Grounding requirements for plug-in LCS-P units via grounded outlet.
Improper grounding can cause electric shock; consult an electrician if unsure.
Do not lift or carry the unit by the charge cord or flexible conduit.
Exercise caution when cleaning the unit and connector cable.
Clean with a soft, damp cloth and mild detergent; avoid abrasives/solvents.
Contact ClipperCreek for service, providing model and serial number.
Details voltage and wiring requirements for single-phase and 3-phase inputs.
Specifies the type and gauge of supplied service conductors.
Table listing LCS models, circuit breaker, current, output power, and cable length.
Lists available NEMA plug types for plug-in LCS models.
Provides enclosure dimensions for the LCS unit.
Specifies the weight of different LCS models with connector and cable.
Lists operating and storage temperature ranges.
Lists agency approvals such as cULus, ETL, FCC.
Details the limited warranty for parts and factory labor.
Outlines the 3-year warranty period and conditions for the product.
Provides instructions on how to obtain warranty service and required information.
Safety warnings for 240V plug-in EVSE, including outlet recommendations.
| SAE J1772 Connector | Yes |
|---|---|
| Enclosure | NEMA 4 |
| Charging Levels | Level 2 |
| Input Voltage | 208V - 240V AC |
| Operating Temperatures | -30°C to 50°C (-22°F to 122°F) |
| Cord Length | 25 feet |
| Mounting | Wall |
| Warranty | 3 years |
| Output Voltage | 208V - 240V AC |
| Charging Current | 16A, 24A, 32A (depending on model) |