EasyManua.ls Logo

CLIVET Box-SM 2 650x650 - User Manual

CLIVET Box-SM 2 650x650
61 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Box-SL 2 650x650
Box-SM 2 650x650
COMPACT FOUR-WAY CASSETTE
Nominal cooling capacity
from 2,6 kW to 5,3 kW
INSTALLATION AND OPERATING MANUAL
Change living home
Series S.IB2+MC2-Y from 35M to 53M
BOX-SM 2 (
for MONOsplit systems):
BOX-SL 2 (for LIGHT Commercial systems):
Series IB2-XY from 27M to 53M
R-32

Questions and Answers

  • M
    Matthew SandovalAug 5, 2025
    Why is my CLIVET Box-SM 2 650x650 Air Conditioner not working?
    • K
      Keith EstradaAug 5, 2025
      Your CLIVET Air Conditioner might not be working due to several reasons: a power failure (wait for the power to be restored), the power switch being off (turn on the power), a burned-out fuse (replace the fuse), dead remote control batteries (replace the batteries), or the unit’s 3-minute protection being activated (wait three minutes after restarting the unit).
  • F
    Francis DavisAug 12, 2025
    What to do if my CLIVET Box-SM 2 650x650 has poor cooling performance?
    • R
      Robert MorganAug 12, 2025
      If your CLIVET Air Conditioner isn't cooling well, it could be due to several factors. First, ensure the temperature setting is lower than the room temperature. Other potential causes include a dirty heat exchanger (clean the heat exchanger), a dirty air filter (remove and clean the filter), blocked air inlet or outlet (turn the unit off, remove the obstruction, and turn it back on), open doors and windows (keep them closed), excessive heat from sunlight (close windows and curtains), or low refrigerant (check for leaks, re-seal if necessary, and top off refrigerant).
  • W
    Whitney BrownAug 19, 2025
    Why does my CLIVET Air Conditioner start and stop frequently?
    • J
      Jason GallagherAug 19, 2025
      Your CLIVET Air Conditioner might be starting and stopping frequently due to several reasons: * Too much or too little refrigerant in the system (check for leaks and recharge the system). * Air, incompressible gas, or foreign material in the refrigeration system (evacuate and recharge the system). * A blocked system circuit (determine which circuit is blocked and replace the malfunctioning piece of equipment). * A broken compressor (replace the compressor). * Voltage that is too high or too low (install a manostat to regulate the voltage).
  • M
    Mr. Matthew CamposAug 27, 2025
    How to fix poor heating performance on CLIVET Air Conditioner?
    • M
      Michael TaylorAug 27, 2025
      If your CLIVET Air Conditioner is not heating well, it could be because the outdoor temperature is lower than 7°C (44.5°F). Other causes include cold air entering through doors and windows (ensure they are closed) or low refrigerant due to a leak or long-term use (check for leaks, re-seal if necessary, and top off refrigerant).

Summary

Accessories

Optional accessories

Lists optional accessories such as remote controllers and decoration panels.

Safety Precautions

Note about Fluorinated Gasses

Provides essential information and precautions regarding the use of fluorinated gasses.

Installation Overview

Installation Order Steps

Outlines the sequence of installation steps with visual aids and page references.

Indoor Unit Installation

Indoor Unit Parts and Safety

Details indoor unit components and specific safety warnings for installation.

Installation Instructions and Distances

Covers installation steps, location selection, and recommended ceiling distances.

Outdoor Unit Installation

Location Selection and Mounting

Guidance on selecting an installation location and mounting the outdoor unit.

Drain Joint and Wall Hole Installation

Instructions for installing the drain joint and drilling a hole in the wall.

Drainpipe Installation

Drainpipe Installation Precautions

Important cautions and notes for proper drainpipe installation and purchasing.

Indoor and Multiple Drainpipe Setup

Details on indoor drainpipe installation and connecting multiple drainpipes.

Refrigerant Piping Connection

Pipe Length and Elevation Requirements

Specifies maximum pipe length and drop height requirements based on models.

Oil Traps and Bend Radius

Guidance on installing oil traps and minimum bend radius for refrigerant pipes.

Pipe Cutting, Flaring, and Connection

Detailed steps for cutting, removing burrs, flaring, and connecting refrigerant pipes.

Wiring

Wiring Safety Precautions and Specifications

Covers safety warnings, power specifications, and cable size requirements for wiring.

Outdoor and Indoor Unit Wiring

Step-by-step instructions for wiring the outdoor and indoor units.

Air Evacuation

Evacuation Safety Precautions

Important safety warnings and procedures before performing air evacuation.

Evacuation Instructions and Valve Operation

Detailed steps for evacuating the system using a vacuum pump and manifold gauge.

Panel Installation

Front Grille Removal and Panel Attachment

Instructions for removing the front grille and attaching the decoration panel.

Intake Grille Mounting and Wiring

Steps for mounting the intake grille and connecting wires from the panel.

Test Run

Pre-Test Run Checks

Confirms all installation points are correct before performing the test run.

Test Run Procedures and Drainage Test

Guides on performing the test run for indoor/outdoor units and a drainage test.

European Disposal Guidelines

WEEE Definition and Disposal Requirements

Explains WEEE directives, definitions of household/professional WEEE, and disposal requirements.

Information Servicing

Area Checks and Work Procedure for Flammable Refrigerants

Safety checks, work procedures, and general area precautions for flammable refrigerants.

Refrigerant Checks and Electrical Component Servicing

Covers refrigerant checks, electrical safety, and repairs to sealed components.

Leak Detection and Removal Procedures

Details leak detection methods, refrigerant removal, and evacuation processes.

Technical Information

MultiSplit Technical Features

Provides technical specifications for multi-split units including refrigerant lines and electrical connections.

Light Commercial Technical Features

Lists technical specifications for light commercial units, including refrigerant lines and electrical connections.

CLIVET Box-SM 2 650x650 Specifications

General IconGeneral
BrandCLIVET
ModelBox-SM 2 650x650
CategoryAir Conditioner
LanguageEnglish