Do you have a question about the CLIVET WSH 120D and is the answer not in the manual?
Provides correct unit installation, use, and maintenance information.
Details indoor installation criteria, including ambient conditions and vibration limits.
Provides steps for making electrical connections, including earthing and cable fixing.
Explains how to use remote controls for unit ON/OFF, set-point changes, and mode switching.
Details communication options like Modbus, LonWorks, and Bacnet with wiring requirements.
Lists essential checks to perform before starting up the unit.
Outlines the sequence of operations required to start up the unit.
Details checks for the refrigerant circuit, including oil stains, pressure, and service outlets.
Guides on checks for the hydraulic circuit, including cleaning, filling, and air evacuation.
Explains checks for the electrical circuit, including grounding, conductor tightening, and phase unbalancing.
Advises on connecting and checking compressor crankcase resistances before start-up.
Introduces the control interface, keypad functions, and unit status indicators.
Explains how to turn the unit on/off using the switch and remote control access.
Describes how thermoregulation is performed based on supply temperature and thermal jump.
Provides guidance on identifying, removing causes, and resetting alarms.
Lists codes for alarms associated with electronic modules, identifying modules and alarm types.
Lists general unit status parameters and their corresponding UM (Units of Measurement).
Details status parameters for Unit 1, Compressor Module 1, and their UM.
States that maintenance must be done by authorized centers or qualified personnel for efficiency and longevity.
Lists controls and checks for the control board, structure, water circuit, electrical, refrigerant, and control systems.
Guides on troubleshooting common alarms and their causes for qualified personnel.
Provides dimensional data for WSH-XSC 65D-80D models, including diagrams and tables.
Presents dimensional data for WSH-XSC 85D-120D models, including diagrams and tables.
Shows dimensional specifications for WSH-XSC 135E-180F models, including diagrams and tables.
Provides updated dimensional data for WSH-XSC 65D-80D models, including OD2 and OD3.
Presents updated dimensional data for WSH-XSC 85D-120D models, including OD2 and OD3.
Shows updated dimensional specifications for WSH-XSC 135E-180F models, including OD2 and OD3.
Details cooling capacity, power input, and EER/ESEER for various models.
Lists heating capacity, power input, and COP for different unit sizes.
Presents electrical data like FLA, FLI, and MIC for different unit sizes.
Specifies the operating limits for external and internal exchangers under cooling conditions.
Provides correction factors for antifreeze solutions based on glycol percentage.
Details calibration settings for various control devices like pressure switches and safety valves.