Code Blue
259 Hedcor Street
Holland, MI 49423 USA
800.205.7186
www.codeblue.com
GU-145-Epage 11 of 23
IA3100
Administrator Guide
Commands During a Call
Command Explanation Format/Default
0 Play 1st message – Play rst message to
guard only (speaker and mic are disabled).
0
1 Extend the off hook time to the dened
time. (see command 63)
1
2 Mic gain – The IA3100 responds with a
single beep when put into high. The IA3100
responds with a double beep when put into
low.
2 / Default = Low
3 Stop playing voice message 3
4 Turn on auxiliary output #1 4
5 Speaker – IA3100 responds with a single
beep when the speaker is turned on. The
IA3100 responds with a double beep when it
is turned off.
5 / Default = On
6 Turn on auxiliary output #2 – Not valid if
auxiliary output #2 is slaved (see
command 44)
6
7 Transmit the ANI (see command 35) 7
8 Speaker volume up 8
9 Speaker volume down 9
*0 Mic – IA3100 responds with a single beep
when the mic is turned on. The IA3100
responds with a double beep when it is
turned off.
*0
*1 Auxiliary outputs stay on for 10 minutes
10 minutes starts when command is given.
*1
*2 Auxiliary outputs stay on for 20 minutes
(See command * 1)
*2
*3 Auxiliary outputs stay on for 30 minutes
(See command * 1)
*3
*4 Turn off auxiliary output # 1 and output #
2 if slaved
*4
*5 Turn off Auxiliary output #2 – Not valid if
auxiliary output #2 is slaved (see command
44)
*5
*6 Disable auxiliary input #1 – Disable for time
dened by command 85 (This allows the
guard to temporarily disable the actions of
auxiliary input #1)
*6
# Hang up # must be held for 2 seconds