16.
12. Adjusting quantity of water. - SERVICE Cater.
This is to improve the water flow into filter holder.
The flow of PDS valve is set to 0.95 litre /minute. Depending on the coarseness and
amount of coffee that’s used when brewing, the flow might need adjustments to prevent
overflow in the filter holder.
Adjusting quantity of water
1. Check the water flow.
This should be 0,95L/minute.
Adjust PDS valve if necessary. See fig.1.
Shall been done by an authorized installation engineer.