EasyManua.ls Logo

Cointra SUPREME 11 B - 5.3 Technical Data Table; 5.4 Wiring Diagram

Cointra SUPREME 11 B
24 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SUPREME B
16
EN
cod. 3541D620 - Rev. 00 - 02/2013
5.2 Hydraulic diagrams
fig. 15 - Water circuit
5.3 Technical data table
5.4 Wiring diagram
fig. 16
Data Unit SUPREME 11 B SUPREME 14 B
Max. heating capacity kW 21.7 26.9 (Q)
Min. heating capacity kW 8.3 10.3 (Q)
Max. heat output kW 19.2 23.9 (P)
Min. heat output kW 7.1 8.8 (P)
Efficiency Pmax % 88.5 88.7
Burner nozzles G20 no. x Ø 10 x 1.25 12 x 1.25
Gas supply pressure G20 mbar 20.0 20.0
Max. gas delivery G20
m
3
/h
2.30 2.85
Min. gas delivery G20
m
3
/h
0.88 1.10
Burner nozzles G30 no. x Ø 10 x 0.79 12 x 0.79
Gas supply pressure G30 mbar 29.0 29.0
Max. gas delivery G30 kg/h 1.70 2.11
Min. gas delivery G30 kg/h 0.65 0.80
Burner nozzles G31 no. x Ø 10 x 0.77 12 x 0.77
Gas supply pressure G31 mbar 37 37
Max. gas delivery G31 kg/h 1.70 2.11
Min. gas delivery G31 kg/h 0.65 0.80
Max. working pressure bar 10 10 (PMS)
Min. working pressure bar 0.20 0.20
DHW flow rate Dt 25°C l/min 11.0 13.7
DHW flow rate Dt 50°C l/min 5.5 6.9 (D)
Protection rating IP X5D X5D
Fume thermostat intervention temperature °C 90
Empty weight kg 11 12
Type of unit
B
11BS
PIN CE 0461CL0984
Gas category II 2H 3+
Fume and air flow rate
SUPREME 11 B SUPREME 14 B
Fume temperature
at Qn
(°C)
Fume flow
rate
Air flow rate
Fume temperature
at Qn
(°C)
Fume flow
rate
Air flow rate
Qn
(g/s)
Qmin
(g/s)
Qn
(m
3
/h)
Qn
(g/s)
Qmin
(g/s)
Qn
(m
3
/h)
G20
148
13 11.1 42
149
16.64 14.2 48
G30
12.2 10.4 35 15.64 13.3 40
89
358
49
42
10 9 8 7 6 5 4 3 2 1
4321
49
(85°C)
126
(90°C)
358
(45°C)
82 188
359
360
blu
blu
giallo
nero
rosso
giallo
rosso
nero
rosso
nero
rosso
rosso
giallo
83
42
44

Related product manuals