PR750H
MECHANICAL MAINTENANCE
1.
Procedure for changing CO
2
filter and gasket on PR750H and PR350H
This section will describe how to changing CO
2
filter and gasket on PR750H and PR350H.
During this operation it’s
important to activate the emergency stop button!
Disassembling the CO2 filter housing
Remove the filter housing by loosening the 4 screws [1] and pull the filter housing end plate
[2], gasket [3], filter [4] out wards. Replace the gasket [3] and the filter [4].
Notice!
It is very important to be careful and not get any dust or dirt into the filter housing under this
Operation,
this could block the Danfoss solenoid valves
.