Care and maintenance
 Keep the device clean and remove any dirt immediately.
Clean the device with a damp cloth and a mild cleaning detergent (soap). Do not use any
cleaning agents containing solvents.
 To change the baeries, open the baery compartment (3) cover using a screwdriver.
Remove the old baeries.
Insert the new baeries in the baery compartment according to the labelling.
Before screwing the cover back on, make sure that the rubber seal is seated in the provid-
ed groove and is not crushed.
Check whether the O-ring of the cover screw connecon is seated in the provided recess.
Correctly aach the cover and screw it back into place.
If the seals are not inserted correctly, this may impair the leak-ghtness of the device.
Replacing the hose

Loosen by turning counter-clockwise
Place the new hose coupling with seal on the thread and ghten in the clockwise direcon.
 There is a parculate screen in the water supply (5) that holds back larger parcles in the
supply water. It is recommended to clean the screen from me to me.
Unscrew the hose connecon as described above.
Use pliers to grab the screen at the protruding screen clip and pull it out.
Clean the screen under owing water and re-insert it.
Screw the hose connecon back on.
 There is also a screen before the water outlet (7). If the amount of water decreases signif-
icantly, this needs to be cleaned.
The hose must be connected to the water outlet only for this reason and this reason only.
At the same me, the second screen at the water supply (5) must be removed (see above).
Then ush the device backwards to remove the deposits.
Then disconnect the hose and re-insert the screen at the water supply.
Nocaon in the display Descripon Reccaon
BAT nocaon in the display area
visualizes that the baery is empty
Change the baeries
Display of a circumferenal line
visualizes that there is no water in
the device
• Ensure a water supply to the device
• Check whether the device inlet is dirty and
remove any dirt if necessary
No nocaon in display aer
pressing the "START/PAUSE” buon
• Change the baeries
• If there is sll no nocaon aer changing
the baeries, then send in the device for repair
