EasyManua.ls Logo

Comfee D80-15EFG - User Manual

Comfee D80-15EFG
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Storage Electric Water Heater
The diagram above is just for reference. Please take the
appearance of the actual product as the standard.
Instruction Manual
For Model:
Thank you very much for purchasing our water heater.
Before installing and operating your water heater, please
read this manual carefully and keep it for future reference.
D30-15EFG
D50-15EFG
D80-15EFG
D100-15EFG

Questions and Answers

  • J
    Jessica HerreraAug 9, 2025
    Why is no water coming out of the hot water outlet of my Comfee D80-15EFG Boiler?
    • S
      Stefanie AlexanderAug 10, 2025
      There could be several reasons why no hot water is coming out: * The running water supply might be cut off. In this case, wait for the water supply to be restored. * The hydraulic pressure may be too low. Wait until the hydraulic pressure increases before using the heater again. * The inlet valve of running water may not be open. Make sure to open the inlet valve.
  • K
    Kristina WashingtonAug 19, 2025
    What to do if my Comfee D80-15EFG water temperature is too high?
    • J
      jessicapopeAug 19, 2025
      If the water temperature is too high, it indicates failures of the temperature control system. Contact professional personnel for repair.
  • G
    gatesmelissaAug 30, 2025
    What to do if my Comfee D80-15EFG Boiler has a water leak?
    • L
      Larry RichardsonAug 30, 2025
      If your boiler is leaking water, it's likely due to a seal problem in the joint of one of the pipes. Try sealing up the joints to resolve the leak.

Summary

Cautions and Safety

Special Cautions for Installation

Critical safety guidelines for earthing, socket rating, wall strength, and pressure relief valve placement during installation.

Unit Installation and Setup

Operating the Water Heater

Alarm and Fault Self-Test

Information on fault codes (E2, E3, E4) indicating dry burning, overtemperature, or sensor issues.

Maintenance and Troubleshooting

Critical Safety for Maintenance

Essential warning to disconnect power supply before commencing any maintenance procedures.

Thermal Switch Reset Procedure

Steps to reset the thermal switch if it has tripped due to overheating or lack of water.

Thermal Switch Reset Warning

Emphasizes that only qualified professionals should reset the thermal switch to prevent accidents.

Comfee D80-15EFG Specifications

General IconGeneral
Voltage220-240V
MaterialStainless Steel
Auto Shut-offYes
Boil-dry ProtectionYes
TypeElectric Kettle
Frequency50Hz

Related product manuals