6
ADJUST MOTOR LIMITS ON PRIMARY REMOTE (IF DESIRED)
e lower and upper limits have been set at
the factory. If you need to make adjustments
to the limits, follow the instructions below.
Please Note: When clearing the factory set
limits, both the upper and lower limits will
need to be reset.
Use the CHANNEL buttons to select the
channel for the shade that needs to be
adjusted. en follow the directions below.
If only adjusting one shade on a channel,
unplug the other shades.
A. Set Lower Limit
B. Set Upper Limit
1
2
3
4
5
Channel
Display
Up
Stop
Down
Channel +
Channel -
C
L
Conrm
Limit
OPERATION RESULT
1
Hold LIMIT button down e motor begins to jog
2
Release the button aer jogging stops e motor is ready for limit setting
3
Press DOWN button e motor will go down continuously
4
When the motor is close to the desired
lower limit, press STOP button on the
remote
e motor stops running
5
Press either the UP or DOWN button e motor runs step by step to adjust lower
limit accurately
6
Conrm the setting by pressing the
CONFIRM button on the remote
e motor jogs and the lower setting is
completed
OPERATION RESULT
1
Press UP button on the remote
transmitter
e motor will go up continuously
2
When the motor is close to the desired
upper limit, press STOP button on the
remote
e motor stops running
3
Press either the UP or DOWN button e motor runs step by step to adjust upper
limit accurately
4
Conrm the setting by pressing the
CONFIRM button on the remote
e motor jogs and the upper setting is
completed