ICE QUALITY IS POOR – CUBES ARE
SHALLOW, INCOMPLETE OR WHITE
Problem
• Cause
Ice machine is dirty
• Clean and sanitize the ice machine
Water filtration is poor
• Replace the filter
Water softener is working improperly (if
applicable)
• Repair the water softener
Poor incoming water quality
• Contact a qualified company to test the quality of
the incoming water and make appropriate filter
recommendations
Water escaping from sump during freeze cycle
• Check standpipe and drain
• Check for water tracking out of water circuit