EasyManua.ls Logo

Compact CMS050A004 - Troubleshooting No Ice Production

Compact CMS050A004
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
46
ICE MACHINE RUNS & NO ICE IS PRODUCED
Problem
• Cause
No water to ice machine
• Correct water supply
Incorrect incoming water pressure
• Water pressure must be 20-80 psi (1.4-5.5 bar)
Spray nozzle is blocked with mineral buildup
• Clean and sanitize the ice machine
Ambient temperature is too high or low
• Ambient temperature must be between 50°F and
110°F (10°C and 43°C)
Thermistor Disconnected or Open
• Refer to thermistor diagnostics

Table of Contents