117
Fig. 45
Attention
Do not run the machine with an empty
oiler tank! The tank must always
contain a minimum of 0.2 l of tool oil.
Danger
Only refill the tool oiler, when the screw
compressor is out of operation and
depressurized!
Only screw off the oiler reservoir, when
the screw compressor is out of
operation and depressurized!
Do not spill any oil!
Watch out for leakage!
The oil dosage is continuously variable at
the adjusting knob.
* Turning the adjusting knob clockwise
(symbol »–«) will reduce the oil flow up
to 0-quantity (i.e. no oil for tool
lubrication in the compressed air).
* Turning the adjusting knob counterclock-
wise (symbol »+«) will increase the oil
flow.
Check the oil level in the depressurized
tool oiler
Fig. 46
* Shut down the screw compressor and
wait until the compressor is
depressurized.
* Unscrew the screw plug.
* The oil must be visible in the oiler
reservoir; refill, if necessary (oil to be
used: CompAir AES 82).
17. Tool oiler option
* Check the seal of the screw plug,
replace if required.
* Screw in the screw plug with the seal
and tighten.
* Check for leaks after start-up of the
screw compressor.