6. Error rectification
[Indication] / Problem Possible cause Remedy
22
Check, repair if necessary
Check that all connecting terminals and
plugs are tight, retighten if necessary
Emergency off is being/has been activated
Emergency off switch defective
Check, replace if necessary
Check, repair if necessary
Motor has been started too often
Limit number of starts/hour
Insufficient motor cooling
Excessive power consumption
Check, replace if necessary
Contactor-type star delta starter defective
Check, repair if necessary
Final compression temperature exceeded
(1)
Approach temperature too high
Unit being operated with enclosure open
Oil injection volume/temperature too low/high
Incorrect oil grade/viscosity
Check, replace oil if necessary
R2 temperature sensor defective
(indication too high)
Check, replace if necessary
Start attempt at too low a temperature
(1)
R2 temperature sensor defective (indication
too low)
Check, replace if necessary
Operating pressure exceeded by 1.0 bar /
14 psi
(1)
Operating pressure exceeded by 1.5 bar /
21 psi
(1)
Pressure losses in the system too high
Network pressure switching points
(4)
too high
External pressure requirement too high
Check remote on-load/off-load
switching points
Intake controller not closing
Pressure sensor B1 or B2 defective
(incorrect indication)
Check, replace if necessary
Faulty supply pressure sensor
Pressure and/or temperature sensor
defective
Cabling to sensor damaged
Check, replace if necessary
Check, replace if necessary