109 - 03 CMOS clock test, CMOS not
properly initialized
110 - 01 Programmable timer load
data test failed
110 - 02 Programmable timer dynamic
test failed
111 - 01 Refresh detect test failed
112 - 01 Speed test slow mode out
of range
112 - 02 Speed test mixed mode out
of range
------------------------------------------------------------------------------
Error
Code Description Recommended Action
------------------------------------------------------------------------------
112 - 03 Speed test fast mode out Replace the system board and retest
of range for error codes 103 - xx through
114 - xx.
112 - 04 Speed test unable to enter
slow mode
112 - 05 Speed test unable to enter
mixed mode
112 - 06 Speed test unable to enter
fast mode
112 - 07 Speed test system error
112 - 08 Speed test unable to enter
auto mode
112 - 09 Speed test unable to enter
high mode
112 - 10 Speed test high mode out
of range
112 - 11 Speed test auto mode out
of range
113 - 01 Protected mode test failed
114 - 01 Speaker test failed
==============================================================================
Table 3-3. Memory Test Error Codes
==============================================================================