e
Refrigerated compressor box 12 / 24 / 230V
Instructions for use
The cooler can be powered from a 12 V or 24 V car or boat plug, or from a standard 230 V socket. It is equipped with
a powerful compressor with refrigerant and can be used as a refrigerator with a temperature of 0 - 10°C or as a freezer
with a temperature of up to -20°C.
The cooler also o󰀨ers an ECO mode to save electricity and an HI mode to quickly cool the contents down to -20°C (at an
ambient temperature of 25°C).
It is also equipped with an intelligent protection system to prevent the discharge of the connected battery and is equipped
with a display with buttons for convenient operation.
The door of the cooler is variable, allowing both longitudinal opening and easy adjustment to transverse opening. The
side handles made of durable plastic make this box easily portable.
The outer shell is made of high-quality silver-coloured painted aluminium, which together with the perfect PU insulation
ensures that the temperature inside the box remains stable for a long time and guarantees very low energy consumption.
The edge of the control panel is completed with a covered USB socket for powering devices with USB connector.
Connecting the appliance to the battery
Plug the 12/24 V cable into a 12 V or 24 V car cigarette lighter socket.
Note! Risk of damage! Disconnect the refrigerator and other appliances from the battery before connecting the bat-
tery to the fast charging device. Overvoltage can damage the electronics of the appliance.
Connection to the 230 V mains
Connect the 230 V adapter cable to a standard 230 V socket and connect the other end of the adapter to the refrigera-
tor.
DANGER! Never handle the connectors or switches with wet hands or when standing on a wet surface. Risk of electric
shock!
To use the appliance on a boat with 230 VAC power supply, you must install a residual current interrupter between the
230 VAC mains and the appliance. Ask an experienced technician for assistance.
USB connector
After removing the cover, the connector can be used to power a USB device using a USB cable (not included)
Model (BLUE) 07 090 (model A30) 07 092 ( model A50)
Model (GREY) 07 094 (model C30) 07 096 (model C50)
Internal volume 30 L 50 L
Power supply 12 / 24 V =
Power input 5A (12V) / 2,5A (24V) 6A (12V) / 3A (24V)
Power supply (230V AC adapter) 230 V ~ 50 Hz
Climate class T / ST / N / SN
Electrical protection class Equipment III
Built-in fuse 15A
Cooling range 20°C to -20°C
Ambient temperature 10°C to 43°C
External dimensions 57.5 x 36.5 x 36 cm 57.5 x 36.5 x 50 cm
Weight 12.9 kg 15,1 kg