17-
e
Troubleshooting
Frequently asked questions
Device not working
Check the power supply
Check the power outlet and connectors to make sure they are in good condition
Check that the device is switched on
Check the built-in fuse
If the Power light is green, wait until the compressor turns on, the cooler is normally operating
Food inside is frozen
Set a higher target temperature
Water sounds are heard inside the refrigerator
This is a normal phenomenon, the refrigerant ow process
In environments with high humidity, water deposits on the door and other external parts
This is a common occurrence, the refrigerator should be wiped regularly with a dry cloth
The refrigerator box is hot at the compressor location when it is running
This is a common occurrence, the compressor generates heat when working, it is necessary to keep the air free
The compressor makes louder noises when starting or stopping
This is a common occurrence, the compressor is made up of metal parts.
Error messages
Code F1 - The battery over-discharge protection has been activated. Switch the protection mode to H3.
Code F2 - Fan overload, switch o󰀨 the appliance, allow it to cool down for 30 minutes and then restart it
Code F3 - Compressor protection, switch o󰀨 the appliance, allow it to cool down for 30 minutes and then restart it
Code F4 - Compressor control unit malfunction. Contact your dealer or professional service
Code F5 - Protection of the control module, switch o󰀨 the appliance, place it in a well-ventilated place and let it cool
down for 30 minutes. Then restart it
Codes F7/F8 - Temperature sensor error, restart the appliance
If F errors persist after restarting the appliance, contact your dealer or professional service.
This appliance is equipped with a built-in fuse of 15 A. It is located inside behind the side cover. When replacing it,
always disconnect the appliance from the power supply.
Refrigerator door opening adjustment
The refrigerator door is variable, allowing both longitudinal opening and easy adjustment to transverse opening.
a) unscrew the steel chain with a screwdriver
b) disconnect both door hinges
c) attach both hinges to the next location
d) screw the steel chain back into the corresponding location using a screwdriver
a)
b)
c)
d)