Compu Pool CPSC Series Manual 9
Salt Level before addition (ppm)
0
500
1000
1500
2000
2500
3000
3500
How Much Salt to Add in pounds
4
117
100
83
67
50
33
17
0
6
175
150
125
100
75
50
25
0
8
234
200
167
133
100
67
33
0
10
292
250
209
167
125
83
42
0
12
350
300
250
200
150
100
50
0
14
409
350
292
234
175
117
58
0
16
467
400
334
267
200
133
67
0
18
525
450
375
300
225
150
75
0
20
584
500
417
334
250
167
83
0
22
642
550
459
367
275
183
92
0
24
701
600
500
400
300
200
100
0
26
759
651
542
434
325
217
108
0
28
817
701
584
467
350
234
117
0
30
876
751
626
500
375
250
125
0
32
934
801
667
534
400
267
133
0
34
992
851
709
567
425
284
142
0
36
1051
901
751
600
450
300
150
0
38
1109
951
792
634
475
317
158
0
40
1168
1001
834
667
500
334
167
0
42
1226
1051
876
701
525
350
175
0
44
1284
1101
917
734
550
367
183
0
46
1343
1151
959
767
575
384
192
0
48
1401
1201
1001
801
600
400
200
0
50
1460
1251
1043
834
626
417
209
0
6.4.1 Table 1 - Salt Table. Locate the column that contains your pool’s current salt
concentration in parts per million at the top of the chart. Then locate the row that
contains the size of your pool in gallons at the left of the chart. Where the column
and row intersect within the chart is the number of pounds of salt required to be
added to your pool.
7.0 INSTALLATION
7.1 Overview
7.1.1 The Power Unit is to be mounted at least 3 feet above ground level, and if possible
protected from direct weather. The Electrolytic Cell is to be plumbed in the return
line to the pool after the pump and filter (and heater, if applicable). Water flow
through the cell can be in either direction, however ideal installation is horizontal,
with the inlet and the outlet pointing down. The three cell lead connectors from the
Power Unit are to be connected to the head of the cell.
Volume of Water in thousands of gallons