- 43 -
button of the thermostat several times, until the set temper-
ature is at least 0.5 °C higher than the temperature of the room.
Following this, the icon indicating that the heating is turned on
should appear on the display of the thermostat within a few seconds.
At the same time, the red LED light on the receiver unit should switch
on to indicate that the receiver unit has received the command of the
transmitter (thermostat).
If it does not happen, the system should be retuned. For this purpose
press the M/A button of the receiver unit and keep it depressed (for
approximately 10 seconds) until the green LED starts ashing. After
this, press the SET” button of the thermostat and keep it depressed
then press the DAY” button of the thermostat and keep it depressed
too (for approximately 10 seconds) until the green LED stops ash-
ing and goes out, so that the receiver unit learns” the safety code
of the transmitter (thermostat). The safety code will not be lost even
during a power outage, the device memorizes it automatically.
ATTENTION! Pressing the “SET” and “DAY” buttons simultane-
ously for 10 seconds generates a new safety code for the thermo-
stat, and the receiver will recognize it only after a repeated tuning.