- 45 -
ATTENTION! If the two parts of the device can only be placed
on the edge of the wireless (radio-frequency) range or out of it
(due to the oor-plan of the house or the shading eect of its
structure), to guarantee the safe wireless connection, place a
COMPUTHERM
Q2RF wireless repeater between the two parts.
10.4 Manual control of the receiver unit
Pressing the MANUAL” button separates the thermostat
from the receiver unit. In this case, the boiler or air conditioner
connected to the receiver unit can only be turned on and
o󰀨 manually, without any temperature inspection. The
continuously illuminated green LED indicates MANUAL
mode. Pressing the M/A button turns on or o󰀨 the boiler.
(The red LED is illuminated when the boiler is turned on). By
pressing the MANUALbutton again, the device quits manual
control and resumes automatic (thermostat-controlled)
operation (the green LED goes out).