44

Once a Network Locaon has been added, it can be easily implemented through the Acve Network Locaon
selecon in the .
ADVANCED ETHERNET PORT SETTINGS
When  (in the lower-le corner) is selected, the following opons also appear:
 - This opon ensures that changes to the units network conguraon will be preserved even
if the device is reset to factory defaults. This seng is disabled by default, and Comrex advises users to be cauous
when enabling it. If the Ethernet parameters are set incorrectly, it is possible to be locked out of the BRIC-Link, and
you will then have to use the Device Manager program‘s Network Recovery Mode (discussed on Page 22) in order
to log into it.
Use With CrossLock - This opon allows for specifying whether this Ethernet port will be used for CrossLock
connecons, and is enabled by default.
 - This opon allows the unit to be idened and congured via broadcast communicaon on the
web-based interface and Device Manager. It is enabled by default.