BRIC-Link features an ability to have an automac backup to a designated remote connecon. A specic backup
connecon (for when the primary fails) is designated when a new remote is created. As shown in ,
selecng the backup opon opens a menu allowing selecon of other outgoing remotes that have been created.

The  feature works in conjuncon with a remote’s Local Timeout parameters dened in the primary
remote’s prole. BRIC-Link can sense an IP Connecon failure, and will wait the dened Local Timeout parameter
in the primary remote’s prole. If the connecon is restored during this me, no backup will occur. If the meout
lapses without re-connecon to the primary remote, BRIC-Link will automacally connect to the designated 
. This connecon will be retained unl the connecon is either manually terminated or the 
funcon reestablishes connecon to the primary remote.