OPERATION AND
MAINTENANCE MANUAL
Gas-fired Steam Humidifier
Nortec GS-Series
2583701_C_EN_1812_Nortec-GS_OM
Humidication and Evaporative Cooling
NORTEC
IMPORTANT! Read and save these instructions. This manual to be left with the equipment.

Table of Contents

Other manuals for Condair Nortec GS Series

Questions and Answers

  • M
    Mandy BallAug 16, 2025
    Why does my Condair Nortec GS Humidifier not turn on when I flip the On/Off switch?
    • L
      Linda JohnsonAug 16, 2025
      If your Condair Humidifier doesn't respond when you turn the On/Off switch on, it could be due to: * Incorrect or no voltage. Check the disconnect switch in the supply line and the fuse between the transformer and the On/Off switch. * The step-down transformer may not be outputting 24 VAC. Check the fuse and measure the VAC on the transformer's primary connections. Replace the transformer if necessary.
  • T
    Thomas JohnsonOct 31, 2025
    What to do if the Condair Humidifier doesn't produce steam or reach the RH setpoint?
    • J
      Jennifer BaxterOct 31, 2025
      If your Condair Humidifier isn't producing steam or reaching the desired RH setpoint, consider these potential causes: * A safety loop might be open. Check if the message "Safety Loop" is displayed. Also, check for 24 VAC at terminal strip pin "2", and ensure all On/Off devices connected to pins "1" and "2" are correctly wired with closed contacts. * The high limit humidistat may be limiting output. Ensure it's not too close to the steam distributor (recommendation is five times the absorption distance or minimum 10 ft (3 m)). Also, verify the high limit setpoint, typically around 80% RH. * There might be no signal on Channel 1. Check the voltage between terminal strip pins "3" and "4". For a demand signal, it needs to be 27% of full scale to start. For a transducer signal, it must ...

Summary

Safety Precautions

Intended Use and Electrical Safety

Specifies humidifier's intended purpose and electrical shock prevention.

Fire, Explosion, and Gas Safety

Critical warnings about fire/explosion hazards and gas leak procedures.

Burn and Hot Surface Hazards

Details risks associated with hot steam vapors and surfaces, and prevention.

ESD and Unsafe Operation Precautions

Warnings about electrostatic discharge and preventing unsafe humidifier operation.

Product Overview

General Description

High-level introduction to the Nortec GS humidifier's features and models.

Functional Description: Combustion System

Explanation of how the humidifier's combustion system operates.

Functional Description: Water Management

Details on how the humidifier manages water levels and related functions.

Operator Interface

Controls and Safety Warnings

Description of the operator interface components and associated electrical safety.

Control Software Overview

Introduction to the humidifier's control software and its functions.

Home Screen and Navigational Elements

Details of the main screen and how to navigate the interface.

Operating Status Descriptions

Explains various operating status messages and icons displayed by the unit.

Maintenance and Fault Status

Information on accessing maintenance reminders, warnings, and fault messages.

Operation Settings

Configuration options for manual capacity, timers, and short cycle functions.

Control Settings: Basic Configuration

Settings for source, control channels, and control modes.

Operation Procedures

System Filling and Safety Tests

Procedures for filling the system and performing ignition safety tests.

Starting the Humidifier

Step-by-step instructions for starting the humidifier after setup or shutdown.

Manual Tank Draining Procedure

Instructions for manually draining the humidifier's tank.

Proper Shutdown Procedure

Detailed steps for safely shutting down the humidifier for maintenance or storage.

Maintenance Procedures

Mandatory Maintenance Schedule

A detailed schedule of required maintenance tasks and intervals.

Fault Isolation and Troubleshooting

Nortec GS Warning and Fault List

Comprehensive list of warning and fault codes with corrective actions.

Fault List: Fill, Drain, and Maintenance Warnings

Specific fault codes related to fill/drain issues and maintenance reminders.

Fault List: RH and Remote Disabled Issues

Fault codes concerning humidity readings and remote disabling.

Fault List: Float and Driver Board Errors

Fault codes related to float sensors and driver board communication.

Fault List: Over-Temperature and Keep Warm Issues

Fault codes related to over-temperature conditions and keep warm function.

Fault List: Ignition and Burner Issues

Fault codes related to ignition failure and burner operation.

Fault List: Gas Valve and Float Level Issues

Fault codes associated with gas valve operation and float level readings.

Fault List: Fill Check and Valve Issues

Fault codes related to fill check faults and dual fill valve issues.

Fault List: Blower Speed Issues

Fault codes for blower operating outside expected speed ranges.

Resetting Fault Status

Procedures for resetting fault conditions, including over-temperature faults.

Condair Nortec GS Series Specifications

General IconGeneral
MaterialStainless Steel
ModelGS Series
TypeSteam Humidifier
ControlOn/Off, Modulating
InstallationWall Mounted
ApplicationsCommercial and industrial