New Function as of Firmware 1.11d:
An optional second parameter can be used to set how long a signal must be pending without
interruption before an alarm is triggered.
SET IN1 <LH/HL/LHL> <TIME> #1513
The parameter <TIME> indicates the time in seconds before an alarm is triggered. The value
range is at:
0 = Off (default) or 1 to 90 (in seconds)
Observe that not using a 2nd parameter will not change the time.
SET IN1 LH 5 #1513 Activation of alarm at HIGH after 5 s
SET IN1 HL #1513 Activation of alarm at LOW and continued at 5 s
The time is displayed in the status text message. The internal time measurement
may be delayed by up to 1 second, so that a set time of 30 s may take up to 31 s
to activate.