INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE.
INSTALLATION AND
OPERATING INSTRUCTIONS
CERTIFIED TO CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.22 AND ANSI Z21.50, FOR VENTED DECORATIVE GAS APPLIANCES.
EN
FR
PG
73
FOR INDOOR USE ONLY
SAFETY INFORMATION
! WARNING
If the information in these instructions
are not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
- Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of
this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbour‟s phone. Follow the gas
supplier‟s instructions.
If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by a
qualified installer, service agency or the supplier.
This appliance may be installed in an
aftermarket, permanently located, manufactured
home (USA only) or mobile home, where not
prohibited by local codes.
This appliance is only for use with the type of
gas indicated on the rating plate. This appliance
is not convertible for use with other gases,
unless a certified kit is used.
CB36NTR / CB36NTRE &
CX36NTR-1 / GCX36NTRE-1
NATURAL GAS MODEL
CB36PTR / CB36PTRE &
CX36PTR-1 / CX36PTRE-1
PROPANE GAS MODEL
SAFETY
BARRIER
CB36
ILLUSTRATED
! DANGER
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this appliance
and shall be installed for the protection of children
and other at-risk individuals.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive,
Crittenden, Kentucky, USA, 41030 Phone 1 (866) 820-8686 www.continentalfi
replaces.com ask@continentalfi re.on.ca
W415-1679 / D / 03.09.18

Table of Contents

Other manuals for Continental Fireplaces CB36NTR

Questions and Answers

  • S
    Sharon RamirezNov 22, 2025
    How to fix a pilot light that will not light on my Continental Fireplaces Indoor Fireplace?
    • B
      Benjamin McdonaldNov 22, 2025
      If the pilot light won't ignite on your Continental Fireplaces Indoor Fireplace, there are several things to check: * First, verify that the sensor wire and igniter wire are connected to the correct terminals on the module (not reversed). * Ensure there are no loose connections, electrical shorts, or grounding issues in the wiring. * Check the igniter spark gap, it should be 1/8” (3.2mm). * Confirm the transformer is installed and plugged into the module, with a voltage between 6.2 and 7.0 volts A.C. when the switch is ON. * If using a battery backup, check the batteries. * Remove and reinstall the wiring harness, verifying continuity of each wire. * Troubleshoot with a simple ON/OFF switch to rule out improper switch wiring. * Ensure the valve and pilot assemblies are pro...
  • K
    Kenneth YoungAug 25, 2025
    What to do if Continental Fireplaces CB36NTR Indoor Fireplace continues to spark and pilot lights, but main burner will not light?
    • S
      Steven RogersAug 26, 2025
      If your Continental Fireplaces Indoor Fireplace continues to spark and the pilot light is on, but the main burner won't light, check the following: * Verify all connections are tight and not grounding out to any metal, especially those from the pilot assembly. * Ensure the flame is engulfing the sensor rod to improve flame rectification. * Clean the sensor rod with a fine emery cloth or synthetic scrub pad to remove any accumulated contamination.
  • T
    Teresa LawrenceAug 26, 2025
    Why is the main burner flame blue, lazy, and transparent on my Continental Fireplaces Indoor Fireplace?
    • J
      John MitchellAug 27, 2025
      If the main burner flame on your Continental Fireplaces Indoor Fireplace is blue, lazy, and transparent, check for a blockage in the vent and remove it. In extreme conditions, ice buildup may occur on the terminal and should be removed. Also, check the venting system parameters, such as the seal, length, and rise.
  • Z
    Zachary WilsonAug 27, 2025
    What to do if I smell exhaust fumes and have headaches from my Continental Fireplaces CB36NTR Indoor Fireplace?
    • A
      Allen AtkinsonAug 27, 2025
      If you smell exhaust fumes in the room or experience headaches when using your Continental Fireplaces Indoor Fireplace, check all seals on the appliance. Also, check if exhaust is re-entering through an open door or window.
  • M
    Monica CarrollAug 29, 2025
    Why are the flames very aggressive on my Continental Fireplaces Indoor Fireplace?
    • S
      shari58Aug 29, 2025
      If the flames on your Continental Fireplaces Indoor Fireplace are very aggressive, first check if the door is ajar and tighten the door clamps if applicable. If the venting action is too great, restrict the vent exit with a restrictor plate.
  • D
    denniskellySep 23, 2025
    Why is there no gas to the main burner on my Continental Fireplaces CB36NTR?
    • D
      dawsonmichaelSep 23, 2025
      If the pilot is burning, but there's no gas to the main burner, with the gas knob on ‘HI’ and the wall switch/thermostat on, for your Continental Fireplaces Indoor Fireplace, purge the gas line. Also, check if you are out of propane gas and fill the tank if necessary.
  • S
    Steven ChaneySep 16, 2025
    Why does the pilot go out when the gas knob is released on my Continental Fireplaces Indoor Fireplace?
    • T
      Tanya StaffordSep 16, 2025
      If the pilot goes out when the gas knob is released on your Continental Fireplaces Indoor Fireplace, allow approximately 60 seconds for the thermocouple to cool.
  • E
    Erik LawrenceSep 18, 2025
    Why is there a white film forming on my Continental Fireplaces CB36NTR?
    • L
      Lori White MDSep 18, 2025
      If you observe a white or grey film forming on your Continental Fireplaces Indoor Fireplace, this is likely sulphur from the fuel being deposited on the glass, logs, or combustion chamber surfaces. Clean the glass.
  • W
    Willie WintersSep 8, 2025
    Why does the pilot light but stop sparking on my Continental Fireplaces Indoor Fireplace?
    • G
      garciajamesSep 8, 2025
      If the pilot lights but stops sparking, or remains lit but the burner won't turn on in your Continental Fireplaces Indoor Fireplace, inspect all wires to ensure good, tight connections and that they are installed correctly. Inspect the wiring harness, ensuring it's tightly connected to the module and that all wires are in the right order.
  • S
    Sylvia ColeSep 5, 2025
    How to fix a pilot light that won't light on a Continental Fireplaces CB36NTR Indoor Fireplace?
    • M
      Misty AlexanderSep 5, 2025
      If the pilot light won't ignite in your Continental Fireplaces Indoor Fireplace, check the wiring to ensure the sensor and igniter wires are correctly connected to the module. Verify there are no loose connections, electrical shorts, or grounding to metal objects. Ensure the igniter spark gap is 1/8” (3.2mm). Check the transformer is installed, plugged into the module, and has a voltage between 6.2 and 7.0 volts A.C. If using a battery backup, check the batteries. Remove and reinstall the wiring harness, verifying continuity of each wire. Ensure the valve and pilot assemblies are properly grounded to the metal chassis.

Summary

Introduction

Rating Plate Information

Explains the information found on the appliance's rating plate for compliance.

Venting

Venting Lengths and Components

Specifies approved venting components and maximum/minimum length requirements.

Typical Vent Installation

Illustrates standard methods for top and rear vent installations.

Minimum Air Terminal Location Clearances

Specifies required clearances for vent terminal locations in various scenarios.

Venting Application Flow Chart

Guides the user through vent configuration choices based on rise and run.

Rear Exit Installation

Provides step-by-step instructions for setting up the rear vent exit.

Top Exit Installation

Provides step-by-step instructions for setting up the top vent exit.

Installation

Horizontal Installation

Guides the installation for venting through an exterior wall.

Vertical Installation

Guides the installation for venting through a roof.

Gas Installation

Details the procedures for connecting and installing the gas supply.

Framing

Minimum Framing Dimensions for CB36; CX36-1

Provides exact dimensions for framing the appliance enclosure.

Minimum Enclosure Clearances

Specifies minimum clearances required for the appliance enclosure.

Minimum Mantel Clearances

Specifies minimum clearances required for mantels above the appliance.

Finishing

Safety Barrier & Door Removal;Installation

Details how to remove and install the safety barrier and glass door.

Wiring Diagram

Wiring Requirements for CB36; CX36-1

Outlines electrical connection and grounding requirements.

CB36 Electronic Wiring Diagram

Illustrates the wiring for the CB36 electronic model.

CX36-1 Electronic Wiring Diagram

Illustrates the wiring for the CX36-1 electronic model.

Operation (Electronic)

Operation (Millivolt)

Adjustment

Maintenance

Annual Maintenance

Details the recommended annual service and checks for the appliance.

Troubleshooting (Electronic)

Troubleshooting (Millivolt)