INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE.
INSTALLATION AND
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
Phone (705)721-1212 • Fax (705)722-6031 • www.continental replaces.com • ask@continental re.on.ca
1.24C
$10.00
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
SAFETY INFORMATION
!
WARNING
- Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbours phone. Follow the gas suppliers
instructions.
If you cannot reach your gas supplier, call the
re department.
- Installation and service must be performed by a
quali ed installer, service agency or the supplier.
If the information in these instructions
are not followed exactly, a re or
explosion may result causing property
damage, personal injury or loss of life.
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
!
DANGER
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this appliance
and shall be installed for the protection of children
and other at-risk individuals.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certi ed kit is used.
Decorative Product: Not for use as a heating appliance.
BARRIER
SAFETY BARRIER
SHOWN WITH GIFK6 FLASHING & FPGI30-K FACEPLATE
CONFORMS TO AMERICAN NATIONAL STANDARDS: ANSI Z21.50, CERTIFIED TO CANADIAN CSA 2.22 FOR VENTED GAS FIREPLACES.
CDI-30N
NATURAL GAS
CDI-30P
PROPANE

Table of Contents

Other manuals for Continental Fireplaces CDI-30N

Questions and Answers

  • O
    Olivia SmithSep 12, 2025
    What happens if the gas piping is undersized for my Continental Fireplaces CDI-30N Indoor Fireplace?
    • D
      Daniel DawsonSep 12, 2025
      If the gas piping is undersized for your Continental Fireplaces Indoor Fireplace, turn on all gas appliances and see if the pilot flame flutters, diminishes, or extinguishes, especially when the main burner ignites. Monitor the appliance supply working pressure. Also, check if the supply piping size is up to code and correct any undersized piping.
  • J
    Jaclyn HamiltonAug 25, 2025
    Why is carbon being deposited on the glass of my Continental Fireplaces Indoor Fireplace?
    • K
      Karen CarlsonAug 25, 2025
      If carbon is accumulating on the glass, logs, rocks, media, or combustion chamber surfaces, check the pressure readings. Inlet pressure can be checked by turning screw (A) counter-clockwise 2 or 3 turns and then placing pressure gauge tubing over the test point. The gauge should read as described on the chart. Ensure the main burner is operating on ‘HI’. Outlet pressure can be checked the same way using screw (B). The gauge should read as described on the chart. Ensure the main burner is operating on ‘HI’. After taking pressure readings, be sure to turn screws clockwise firmly to reseal, but do not over torque.
  • T
    thomas95Aug 25, 2025
    What to do if flames are touching the glass in my Continental Fireplaces Indoor Fireplace?
    • G
      Gregory JohnsonAug 26, 2025
      If the flame is hitting the glass, logs, rocks, media, or combustion chamber, first ensure the media is positioned correctly within the appliance. Try opening the air shutter to increase the primary air. Check the input rate by verifying the manifold pressure and orifice size as specified on the rating plate. Make sure the door gasketing is intact and the seal is tight. Verify vent liners are free of holes and well-sealed at all joints. Ensure the minimum rise per foot (meters) has been adhered to for any horizontal venting.
  • E
    Elizabeth CarrSep 23, 2025
    How to repair grounding remote wall switch wire in Continental Fireplaces Indoor Fireplace?
    • M
      Mark SnyderSep 23, 2025
      If the remote wall switch wire of your Continental Fireplaces Indoor Fireplace is grounding, check for a ground (short), repair the ground, or replace the wire.
  • A
    austin09Sep 12, 2025
    What to do if my Continental Fireplaces Indoor Fireplace appliance is spilling?
    • J
      jessicarodriguezSep 12, 2025
      If the Continental Fireplaces Indoor Fireplace appliance is spilling, ensure the exhaust bracket gasket seal is intact. Check the door seal and relief flap seal. Inspect for any chimney blockages and ensure the chimney is installed according to the building code. Also, verify that the room isn't experiencing negative pressure; if it is, increase the fresh air supply. Finally, check the cap gasket on the flue pipe assembly.
  • J
    Jamie ParkerSep 16, 2025
    What to do if door is ajar on Continental Fireplaces Indoor Fireplace?
    • K
      Kimberly FischerSep 16, 2025
      If the door of your Continental Fireplaces Indoor Fireplace is ajar, ensure the mechanical means of securing the door is providing a tight seal.
  • M
    mfisherSep 5, 2025
    What to do if my Continental Fireplaces CDI-30N Indoor Fireplace is out of propane gas?
    • T
      Tyler MerrittSep 5, 2025
      If your Continental Fireplaces Indoor Fireplace is out of propane gas, fill the tank.
  • A
    angelareidSep 5, 2025
    What to do if my Continental Fireplaces CDI-30N Indoor Fireplace has a pilot flame that is not engulfing the thermocouple?
    • U
      uwheelerSep 5, 2025
      If the pilot flame on your Continental Fireplaces Indoor Fireplace is not engulfing the thermocouple, gently twist the pilot head to improve the flame pattern around the thermocouple.
  • W
    William HaneySep 23, 2025
    Why does main burner come on when gas knob is turned on in Continental Fireplaces Indoor Fireplace?
    • K
      Kathryn AdamsSep 23, 2025
      If the remote wall switch is in the 'OFF' position but the main burner comes on when the gas knob is turned to the 'ON' position on your Continental Fireplaces Indoor Fireplace, reverse the switch.
  • J
    Jennifer WatsonAug 30, 2025
    How to fix a faulty thermostat or switch in Continental Fireplaces CDI-30N Indoor Fireplace?
    • E
      Edward MorrisonAug 30, 2025
      If you have a faulty thermostat or switch, replace it.