- Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fi re department.
- Installation and service must be performed by a qualifi ed installer, service agency, or the supplier.
WARNING
!
ENGLISH
For indoor use only
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
OWNER’S MANUAL
CL38 / CL50
SAFETY INFORMATION
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030
Phone 1 (866) 820-8686 • www.continentalfi replaces.com • hearth@continentalproducts.com
Linear Gas Appliance

Other manuals for Continental Fireplaces CL50

Questions and Answers

  • J
    Jessica MayoAug 12, 2025
    Why is my Continental Fireplaces CL50 beeping?
    • B
      Bryan BurnsAug 12, 2025
      If the motor is turning and frequent beeping occurs with your Continental Fireplaces Indoor Fireplace, replace the receiver batteries. This indicates that the receiver batteries are low.
  • J
    James BensonAug 19, 2025
    Why is the flame on my Continental Fireplaces CL50 Indoor Fireplace weak and blue?
    • J
      Jeffery OrtegaAug 19, 2025
      If the main burner flame on your Continental Fireplaces Indoor Fireplace is blue, lazy, and transparent, it could be due to several reasons: * There might be a blockage in the vent, in that case remove the blockage. * The installation might be incorrect, so refer to the 'VENTING' section to ensure correct installation. * The appliance might be over-fired or under-fired, thus check pressure readings and ensure the main burner is operating on 'HI'.
  • K
    Katie FosterAug 27, 2025
    Why won't the pilot light on my Continental Fireplaces CL50 spark?
    • C
      Courtney WalkerAug 27, 2025
      If the pilot won't light and makes noise with no spark at the pilot burner for your Continental Fireplaces Indoor Fireplace, verify the thermocouple/sensor is clean and the wiring is undamaged. This may be caused by wiring issues such as short, loose, or damaged connections (poor flame rectification).
  • C
    Christopher KingSep 3, 2025
    How to reset ignition box on Continental Fireplaces CL50 Indoor Fireplace?
    • N
      Nichole JonesSep 3, 2025
      If the pilot will not light, makes no noise, and there is no spark at the pilot burner on your Continental Fireplaces Indoor Fireplace, the ignition box may have been locked out. To reset the ignition box, turn off the power supply and remove batteries (if used) from the back-up battery pack.

Continental Fireplaces CL50 Specifications