Revised: 25/06/2008 Printed: 3/12/2009
The Genuine
A Great Way To Keep Warm
Coonara “Grange Classic
One of the world’s most powerful efficient gas
log space heaters
CUSTOMER OPERATING INFORMATION
&
INSTALLATION INSTRUCTIONS
Serial Number of Heater
: ____________
Model:
________________
Grange Classic Gas Heaters
ARE MANUFACTURED BY
SHAMIC SHEETMETAL
SHAMIC SHEETMETALSHAMIC SHEETMETAL
SHAMIC SHEETMETAL
(AUST.) PTY. LTD.
PO BOX 8, KILSYTH, VIC. 3137
PH: 03 9737 5300 FAX: 03 9761 6455
www.shamicheating.com.au

Questions and Answers

  • K
    Kara PerkinsAug 13, 2025
    Why does my Coonara Heater fail to ignite or go out after igniting?
    • E
      efieldsAug 13, 2025
      If your Coonara Heater fails to ignite or ignites and then goes out, several factors could be at play. First, ensure that the gas supply is connected, fully purged, and at the appropriate pressure. Next, verify that the unit is properly plugged in and the switch is turned on, and check the supply fuse. Also, ensure there's sufficient time (at least 15 seconds) between ignition attempts to allow the combustion chamber to purge. It's also worth checking that all internal wiring plugs are correctly connected and located. The gas valve pressures may need adjustment. Finally, ensure the combustion fan and air pressure switch are working, and that the active, neutral, and earth wires are correctly oriented and connected.
  • A
    Alisha WilliamsAug 17, 2025
    Why is the room fan not working on my Coonara Grange Classic Heater?
    • A
      Alexis GutierrezAug 17, 2025
      If the room fan in your Coonara Heater isn't operating, remember that it has a delayed start and won't activate until the unit warms up. Check the wiring to ensure it's properly connected. Make sure the fan is installed in the correct location and that nothing is blocking it. If blocked, remove and clean the fan.
  • K
    katie68Aug 20, 2025
    What to do if my Coonara Heater cuts out and cycles on and off?
    • A
      Amanda WilliamsAug 20, 2025
      If your Coonara Heater unit cuts out after running for a while and then cycles on and off, this could be due to a heat exchanger blockage, which requires cleaning. Ensure the correct gas type is being used, with the appropriate injector size and pressure setting. Also, consult the section addressing issues with the room fan, as this could be related.
  • X
    xcarrilloAug 25, 2025
    Why is my Coonara Grange Classic not heating the room?
    • M
      Morgan GonzalezAug 26, 2025
      If your Coonara Heater is not heating, check the gas type, injector size, and pressure setting to ensure they are correct. Also, inspect the injector, burner supply pipe, and valve for any foreign material that may be causing a blockage. You may also need to consult the section on the room fan, as its operation could be related to heating performance.
  • A
    Ashley ManningAug 28, 2025
    Why does my Coonara Heater have excessive flame height?
    • N
      Nicholas BurnsAug 29, 2025
      If your Coonara Heater exhibits excessive flame height, it might be due to an incorrect gas type or pressure setting. Verify that you're using the correct gas type, injector size, and pressure setting for your unit.
  • W
    William GarnerSep 1, 2025
    What to do if my Coonara Heater won't operate on low?
    • L
      Lisa DyerSep 1, 2025
      If your Coonara Heater will not operate on low, you should adjust the valve. Also, check the wiring to ensure that it is correctly connected and not loose.
  • H
    hhughesSep 5, 2025
    What causes excessive flame lift off in my Coonara Grange Classic?
    • N
      Nicole ChavezSep 5, 2025
      Excessive flame lift off in your Coonara Heater can be caused by a blockage in the flue or inlet. Clear any obstructions to resolve this issue. Incorrect flue installation leading to recirculation of flue gases can also cause this problem.
  • K
    Karen MillerSep 9, 2025
    How to fix a Coonara Heater burner that won't spark?
    • M
      Marco MaldonadoSep 9, 2025
      If the burner on your Coonara Heater won't spark, it might be because the gap between the burner and sparker is not the specified 3mm. To fix this, remove the front burner cover using pliers and carefully bend the tags holding the sparker, being cautious not to bend the sparker itself.

Summary

Product Features

Safety Precautions

Installation Safety Requirements

Mandates installation by an authorized person, adhering to codes and manufacturer instructions.

Customer Operating Instructions

Safety Features

Automatic Shut-Off

Automatically cuts off gas supply if flame extinguishes or during overheating conditions.

Over Temperature Protection

Protects the appliance from overheating by shutting off gas supply due to fan failure or airway blockage.

Installation Instructions

Gas Pressure to Gas Valve

Procedure for setting gas pressure to the gas valve, applicable to NAT and LPG.

Pressure Adjustments

840 Outlet Pressure Adjustment

Procedure for adjusting outlet pressure on the 840 model using specific screws.

843;845 Outlet Pressure Adjustment

Guide for adjusting maximum and minimum outlet pressure on 843/845 models using nuts and screws.

Wiring Diagram

Warranty Information

Trouble Shooting Guide

Coonara Grange Classic Specifications

General IconGeneral
TypeWood Heater
FuelWood
ConstructionSteel
Firebox MaterialSteel
Maximum Log LengthUp to 500mm
Warranty10 years
Emissions1.5g/kg
Flue Size150mm
Emissions StandardAustralian Standards AS/NZS 4012/4013