S225-12-1
25
!
SAFETY
FOR LIFE
6. Remove the P1 and P2 slip ring from the moveable
contact and Geneva Gear Assembly by lifting the ring
stud assembly upward on the opposite side of the
moveable contact button. To help in identifying the
slip ring see Figure 56. Slide the slip ring out of from
between the moveable contact button. (See Figure
55.) Repeat this process for the second slip ring stud
assembly.
Figure 56.
Slip ring.
Figure 55.
Slip ring removal.
P1 & P2 Slip Rings
Moveable Contacts
Installing New Main Moveable and Geneva
Assembly
7. Place one of the Slip Ring Studs (see Figure 57)
assemblies over the hub of the moveable contact and
Geneva gear assembly (see Figure 58). When putting
the slip ring on the Geneva gear, angle the ring so that
the ring can be inserted between the moveable contact
buttons on the lower left hand moveable contact. (See
Figure 58.)
Figure 57.
Moveable contact assembly.
Hub
Figure 58.
Slip ring & moveable contact assembly.
Moveable Contact Buttons
Slip Ring