2KZ/2K0
1-5-13
(4) Detaching and refitting the registration cleaner
Procedure
1. Open the front cover. (See page 1-5-3)
2. Open the duct cover. (See page 1-5-15)
3. Set the cleaner lever (yellow) up and
draw the registration cleaner frontward.
4. Check or replace the registration
cleaner and refit all the removed parts.
Figure 1-5-21
(5) Detaching and refitting the MP tray
Procedure
1. Open the MP tray.
2. Release two fulcrums of the MP tray by
using a flat screwdriver.
3. Pull two straps upwards to remove.
4. Remove the MP tray.
Figure 1-5-22
_
q
Registration cleaner
Cleaner lever
(yellow)
Flat screwdriver Flat screwdriver
Flucrum
MP tray
Straps
Flucrum