CH750, CH751 & CH951 CHILLERS
Operators & Installation Manual
Release Date: April 19, 2002
Publication Number: 91256
Revision Date: March 25, 2014
Revision: F
Visit the Cornelius web site at www.cornelius.com
for all your Literature needs.

Questions and Answers

  • G
    George ElliottJul 30, 2025
    How to troubleshoot a Cornelius Chiller that won't turn on?
    • B
      bailey77Jul 30, 2025
      If the Cornelius Chiller isn't operating and the power light is off, first, ensure the unit is receiving power by checking the main disconnect fuses, wiring, and power lead. Then, inspect the wiring for loose or poor connections and correct them. If those steps don't resolve the issue, the control power switch might be defective and require replacement. Also, the overload device might be open, in that case, allow the compressor to cool, then install a new overload device, replacing the compressor if needed. Another potential cause is an inoperable relay, which would need replacement. Finally, verify that the input voltage is within the required nominal range of +/- 10%.
  • T
    tstricklandAug 8, 2025
    What to do if Cornelius CH750 Chiller is not cooling enough?
    • A
      amandasellersAug 9, 2025
      If your Cornelius Chiller isn't cooling adequately, start by cleaning the condenser. If the fan motor isn't operating freely, replace the fan blade and/or motor if necessary. Also, check for water circulation issues. If the water is not circulating, see 'No Circulation of Chilled Water'. If the problem persists, the unit might be low on refrigerant and needs to be charged. Lastly, an inoperative temperature control could be the cause, requiring thermostat replacement.
  • S
    Shannon Banks IIIAug 18, 2025
    Why is there no chilled water circulation in my Cornelius Chiller?
    • R
      Robert AtkinsAug 19, 2025
      If there's no circulation of chilled water in your Cornelius Chiller, first inspect the lines to and from the chiller for any restrictions and remove any obstructions. Next, ensure that the tank is full. Finally, check the pump for obstructions or a binding impeller; replace the pump and/or motor if necessary.

Summary

Safety Instructions

Qualified Service Personnel Requirement

Emphasizes that only trained technicians should service the unit.

Safety Precautions

Power Disconnect Warning

Critical warning to disconnect power before servicing to prevent injury or death.

Installation Instructions

Start-Up and Operation

Maintenance Procedures

Maintenance Safety Warning

Essential safety warning to disconnect power before performing any maintenance work.

Service and Repairs

Service Safety Warning

Safety warning for servicing; emphasizes disconnecting power.

Troubleshooting Guide

Troubleshooting Safety Warning

Safety warning to disconnect power before attempting any troubleshooting.