Energize R134a 60Hz
Manual operation undercounter cooler
Energize R134a 60Hz
Page 22
Cornelius Deutschland GmbH
Document no: TD1005601EN
Version A, 24.09.2019, Index 0
10 Problems and Troubleshooting
Before looking for problems with the dispensing equipment, first check:
Is the electricity to the device interrupted?
Is the flow of water to the device interrupted?
Are the beverage containers empty?
Is the CO
2
-cylinder empty?
Type of problem
Cause
Remedy
Beverage too warm compressor
is running
Condenser dirty
Use brush to clean condenser
louvers
Beverage too warm, compressor
not running
Compressor defective
Electric control defective
Call service technician
Check whether the carbonator
motor is running; if
not, call service technician
Beverage foams at a tap
Syrup stored too long
Connect with fresh product
Beverage foams at all taps
CO
2
-pressure too high
All syrups enriched with CO
2
All beverages stored too warm
Too much beverage being dispensed
Set CO
2
pressure
Connect container with fresh
product
Check storage temp
Note out-put capacity
CO
2
-volume in the beverage is
too low
Air in carbonator
Beverage dispense rate at capacity
CO
2
-cylinder empty
Valve on CO
2
-cylinder is closed
Valve on pressure regulator is closed
CO
2
-pressure too low
Water temperature to high
Bleed air
Reduce dispense rate
Change CO
2
cylinder
Open CO
2
valve
Open valve
Adjust valve to pressure
Ice bank used up, allow time to
build new ice bank
Too much or not enough syrup
in the beverage
Regulator in tap is blocked
Tap is misaligned
Pressure for syrup too low or to high
Call service technician
Call service technician
Adjust CO
2
-pressure
Tap just outputs concentrate
Note! Only with mechanical taps
Carbonator pump is not running
Check if water feed line is open
Check if water flow pressure of 2
bar
Check if Carbonator pump is
running, if not call service
technician