EasyManua.ls Logo

Cornelius Energize 4 - 11 Diagnostic Messages

Cornelius Energize 4
33 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Energize R134a 60Hz
Manual operation undercounter cooler
Energize R134a 60Hz
Page 23
Cornelius Deutschland GmbH
Document no: TD1005601EN
Version A, 24.09.2019, Index 0
11 Diagnostic messages
Message
Cause
Remedy
CO
2
pressure NOK
CO
2
inlet pressure below operating
pressure of 6 bar
Check CO
2
supply
Change CO
2
cylinder
Adjust pressure regulator
Check CO
2
pressure switch
Check electric connections
Carbonator pump NOK
Carbonator pump pressure below
operation pressure of 10 bar
Check carbonator bowl
Check CO
2
supply
Change carbonator pump
Change carbonator pump motor
Check Carbonator pressure switch
Check electric connections
Water inlet pressure NOK
H2O inlet pressure below operating
pressure of 0,2 bar
Check H2O supply
Check electric connections
Agitator NOK
Agitator RPM speed below adjusted
settings of 1570 min
-1
respectively 3880
min
1
Check agitator motor
Check electric connections
Water bath temperature NOK
Water bath temperature above
operating temperature of or dispense
rate at capacity
Check temperature probe
Check electric connections
Ice bank used up, allow time to build
new ice bank and / or reduce dispense
rate
Ambient temperature NOK
Ambient temperature above maximum
specification of 40°C
Check temperature probe
Check electric connection
Improve room ventilation
Soda temperature NOK
Soda return temperature above
operating temperature of max. 2°C, or
dispense rate is at capacity
Check temperature probe
Check electric connection
Ice bank used up, allow time to build
new ice bank and / or reduce dispense
rate
Hot gas temperature NOK
Condenser temperature above
operating temperature of max. 120°C
Check temperature probe
Check electric connections
Provide sufficient ventilation
Clean condenser fins
Compressor run time
For information only
Carbonator pump run time
For information only
Voltage check NOK
Power supply out of specification
Check power supply conditions