Note: The specifications are subject to change without notice.
3
Specification
Model No.
Item
SK1000-112 SK1000-124 SK1000-148 SK1000-212 SK1000-224 SK1000-248
Continuous Output Power 1000W
Maximum Output Power 1100W
Surge Rating (Max) 2000W
Input voltage 12V 24V 48V 12V 24V 48V
Output Voltage
100 / 110 / 120V +/- 3% 220 / 230 / 240V +/- 3%
Frequency
(Switch Selectable)
50 / 60Hz +/- 0.05%
Output Waveform Pure Sine Wave ( THD < 3% )
Efficiency (full load) Max.
*1
89.0% 92.0% 93.0% 91.0% 94.0% 95.0%
No Load Current Draw (Max.) 1.43A 0.75A 0.38A 1.25A 0.65A 0.35A
Stand-By Current Draw (Max.) 0.25A 0.15A 0.09A 0.25A 0.15A 0.09A
Input Voltage Regulation
10.5-15
VDC
21.0-30
VDC
42-60
VDC
10.5-15
VDC
21.0-30
VDC
42-60
VDC
Input Level Indicator
Load Level Indicator
Red / Orange / Green LED
Failure Indicator Red LED
Protection
Overload, Short Circuit, Reverse Polarity (Fuse),
Over / Under Input Voltage, Over Temperature.
Remote Control Unit CR-6 / CR-7 / CR-8 Optional
Safety Certification UL458 EN60950-1
EMC FCC Class A
EN55022: 1997
EN55024: 1997
EN61000-3-2: 1998
EN61000-3-3: 1995
e-mark
e13 022694
Operating Temperature Range
0 - 40
Storage Temperature Range
-30 to 70
Cooling Loading controlled cooling fan
Dimensions 383(L)*182(W)*88(H)mm / 15.08(L)*7.17(W)*3.46(H) Inch
Weight 4 kg / 8.8 Lbs.