30
Others
Water Filtration System Performance Data Sheet
Brand: Metro Model: CHP-04AR
ThissystemhasbeentestedandcertiedbytheWaterQualityAssociationaccordingtoNSF/ANSI42,53,and58for
thereductionofthesubstanceslistedbelow.Theconcentrationoftheindicatedsubstancesinwaterenteringthe
systemwasreducedtoaconcentrationlessthanorequaltothepermissiblelimitforwaterleavingthesystem,as
speciedinNSF/ANSI42,53,and58.
Substance
Max.Allowable
Concentration
(mg/L)
Average
Inuent
(mg/L)
Average
Euent
(mg/L)
Minimum
Percent
Reduction(%)
Average
Percent
Reduction(%)
Arsenic(Pentavalant) 0.010 0.05 0.006 79.1 87.7
Barium 2.0 10 1.4 83.5 86.6
Radium226/228 5pCi/L 25pCi/L 5pCi/L N/A N/A
Cadmium 0.005 0.031 0.002 89.0 92.7
Chromium(Hexavalent) 0.1 0.358 0.023 93.8 95.1
Chromium(Trivalent) 0.1 0.367 0.028 93.8 95.7
Lead 0.010 0.153 0.005 93.6 95.1
Nitrate/Nitrite 10 29.6 4.8 78.5 83.7
Selenium 0.05 0.117 0.003 96.0 97.8
TDS <187.5 741.5 14.5 97.3 98.0
AestheticChlorine
INNOSENSE ≥50% 2.07 0.56 54.53 72.8
FINEPOSTCARBON ≥50% 1.96 0.53 55.0 72.8
VOC*
INNOSENSE ≥95%reduction 0.327 0.0052 96.20 98.4
FINEPOSTCARBON ≥95%reduction 0.317 0.005 96.2 98.5
Whiletestingwasperformedunderlaboratoryconditions,actualperformancemayvary.
General Operating Information:
RatedCapacity
INNOSENSEFILTER
359gallons(forVOC)
7,523gallons(forAestheticChlorine)
POST-CARBONFILTER
402gallons(forVOC)
1,453gallons(forAestheticChlorine)
Min-Maxoperatingpressure: 10~120psi(0.7~8.4kgf/cm
2
)
Min-Maxfeedwatertemperature: 41~95ºF(5~35ºC)
RatedServiceFlow
0.07GPM(forVOC)
0.5GPM(forAestheticChlorine)
DailyWaterProductionRate 86.2GPD
ProductEciencyRating 38.7%
ElectricalRequirements: 120Vac/60Hz
• Donotusewithwaterthatismicrobiologicallyunsafeorofunknownqualitywithoutadequatedisinfection
beforeorafterthesystem.
• Refertotheownersmanualforspecicinstallationinstructions,manufacturer’slimitedwarranty,user
responsibility,andpartsandserviceavailability.
• Theinuentwatertothesystemshallincludethefollowingcharacteristics:
o Noorganicsolvents
o Chlorine:<2ppm
o pH:7-8
o Temperature:41~95ºF(5~35ºC)
o Iron:<2ppm
o Turbidity:<1NTU
o Hardness:<1000mg/L