32
Others
PERFORMANCE DATA SHEET
|
CHP-04AR
StateofCalifornia
DepartmentofPublicHealth
Water Treatment Device
Certicate Number
08 - 1905
DateIssued:June24,2008
Trademark/Model Designation
Replacement Element(s)
MetroCHP-04AR WJSF14-PLUSPlusSedimentFilter
WJCF14-PREPre-carbonFilter
WJMF14-75ROMembraneFilter
WJFCF14-POSTPost-carbonFilter
WJUVF-4W-PUMPUVBulb
Manufacturer:WoongjinCowayCoLTD
Thewatertreatmentdevice(s)listedonthiscerticatehavemetthetestingrequirementspursuanttoSection116830oftheHealth
andSafetyCodeforthefollowinghealthrelatedcontaminants:
Microbiological Contaminants and Turbidity
Inorganic/Radiological Contaminants
None Arsenic(Pentavalent)
1
Barium
Cadmium
Chromium(Hexavalent)
Chromium(Trivalent)
Lead
Nitrate/Nitrite
2
Radium226/228
Selenium
Organic Contaminants
VOCs
Alachlor Endrin Simazine
Atrazine Ethylbenzene Styrene
Benzene EDB 1,1,2,2-Tetrachloroethane
Carbofuran Haloacetonitriles(HAN) Tetrachloroethylene
CarbonTetrachloride Bromochloroacetonitrile Toluene
Chlorobenzene Dibromoacetonitrile 2,4,5-TP(Silvex)
Chloropicrin Dichloroacetonitrile TribromoaceticAcid
2,4-D Trichloroacetonitrile 1,2,4-Trichlorobenzene
DBCP Haloketones(HK) 1,1,1-Trichloroethane
o-Dichlorobenzene 1,1-Dichloro-2-Propanone 1,1,2-Trichloroethane
p-Dichlorobenzene 1,1,1-Trichloro-2-Propanone Trichloroethylene
1,2-Dichloroethane Heptachlor Trihalomethanes(THMs)
1,1-Dichloroethylene HeptachlorEpoxide Bromodichloromethane
cis-1,2-Dichloroethylene Hexachlorobutadiene Bromoform
trans-1,2-Dichloroethylene Hexachlorocyclopentadiene Chloroform
1,2-Dichloropropane Lindane Chlorodibromomethane
cis-1,3-Dichloropropylene Methoxychlor Xylenes
Dinoseb Pentachlorophenol
Rated Service Capacity: 359 gal
Rated Service Flow: 0.07 gpm
Do not use with water that is microbiologically unsafe or of unknown quality, without adequate disinfection
before or after the system.
1
Claimsforarsenicreductionshallonlybemadeonwatersuppliesmaintainingdetectableresidualfreechlorineatthe
reverseosmosis(RO)systeminlet.Watersystemsusinganin-linechlorinatorshouldprovideaminimumof1minute
chlorinecontacttimebeforetheROsystem.
2
Thissystemisacceptablefortreatmentofinuentconcentrationsofnomorethan27mg/Lnitrateand3mg/Lnitritein
combinationmeasuredasNandiscertiedfornitrate/nitritereductiononlyforwatersupplieswithapressureof280kPa
(40psig)orgreater.Asamplingandanalysistestkitfornitrateisprovidedforcheckingtheperformanceofthissystem.
Frequentanalysisisencouraged.

Related product manuals