10
9
WATER FILTRATION PROCESS / INSTALLATION PRECAUTIONS
How to Use
INSTALLATION PRECAUTIONS
1. Close main water supply valve to separate the faucet.
2. Apply the teon tape on the adaptor and t it to the
pipe.
3. Connect the faucet with the adaptor.
4. Connect 1/4 inch orange tubing with the connector
on the adaptor.
5. Open the feed valve to supply water to the ltration
system.
The summary for the proper installation of the water ltration device
Do not turn the water pipe.
Install the adaptor with connector to the cold water pipe.
Flush water through each lter at least 5 minutes before
Connection.