6 www.CookingPerformanceGroup.com
USER MANUAL
1. Turn o the manual valve and wait 5 minutes to clear air gas.
2. Turn all knobs to "OFF" position.
3. Hold an ignition source (match) at pilot. When the ame is established, remove ignition source.
4. Turn burner knobs to "ON". If the burner does not ignite, promptly open pilot valve more. If pilot ame appears
larger than necessary, turn it down and reset burner ignition. The pilot ame should be as small as possible but
large enough to guarantee reliable ignition of burners when knobs are turned to "ON".
LIGHTING INSTRUCTIONS
The pilot light on the griddel has been pre-set at the factory. A screwdriver may be required for the initial lighting
to adjust the ame for your elevation.
LIGHTING MAIN BURNER:
CPG MANUAL GRIDDLES
To light burner, turn knob to "ON." Then back o to the desired ame level. The range of adjustment is virtually
innite between "ON" and "OFF".
CPG THERMOSTATIC GRIDDLES
1. Select the burner required, depress and turn the corresponding gas control knob counter-clockwise
to "PILOT" position.
2. With the gas control knob depressed, manually light pilot burner.
3. Release gas control knob approximately 10-20 seconds after lighting pilot burner.
4. Pilot burner should stay lit. Provided it does not, repeat steps 2 and 3.
5. Rotate gas control knob counter-clockwise to desired temperature mark.
6. The main burner will now be ignited automatically.