EasyManua.ls Logo

Craftsman CMHT77639 - Specifications; Information Codes

Craftsman CMHT77639
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
E
Specifications
Range 11.8in to 165ft (0.3m to 50m)
Measuring Accuracy* ± 1/16in (± 1.5mm)*
Smallest Unit Displayed ± 1/16in (± 1mm)
Laser Class Class 2 (IEC/EN60825-1: 2014)
Laser Type ≤ 1.0mW @ 620-690nm
Laser/Backlight Automatic Switch-off 60s
Unit Automatic Switch-off 120s after the Laser is Off
Continuous Measuring Yes
Area/Volume Yes
Indirect Height/Double Indirect Height Yes
Battery Life Up to 3000 Measurements
Dimension (H x D x W) 4.63 x .94 x 1.81in (118 x 24 x 46mm)
Weight 3.04oz (86g)
Storage Temperature Range 14° F ~ 140° F (-10° C ~ +60° C)
Operating Temperature Range
32° F ~ 104° F (0° C ~ +40° C)
Protection Class
IP40
*
Measuring Accuracy depends on the current conditions:
Under favorable conditions (good target surface and room temperature), up to 30ft (10m).
Under unfavorable conditions (bright sunlight, a very weak reflecting target surface, or large temperature fluctuations), the error
can increase by to ± 0.002 in/ft (± 0.15mm/m) for distances over 30ft (10m).
Information Codes
If IC appears on the display window with a Code number, perform the corresponding Corrective Action.
Code Description Corrective Action
255 Cannot Measure Switch the device on/off several times. If the error still occurs, return the
defective device to the Service Center or distributor. Refer to the Warranty.
301 Trigonometric When calculating the height of a tall building, code 301 will appear if you
measure a longer distance after a shorter distance.
401 Communication If you take a measurement too quickly after taking another measurement,
code 401 will appear.
501 Out of Temperature
Range
Allow the device to cool down or warm up to a temperature within the range
32° F ~ 104° F (0° C ~ +40° C)