Accuracy: ±1% of rated maximum transducer capacity.
Overload Capacity: 110% of stated maximum transducer capacity.
Zero Drift: <0.1% of rated maximum transducer capacity.
Operating Temperature Range: +5 to +40 degrees Celsius
Temperature Stability: ±0.1% per degree Celsius.
Sealing: IP40.
Humidity: 5% to 75% non condensing.
Serial Interface: 9 way female ‘D’ connector.
Frequency Response: User selectable in 14 steps from 75Hz to 6144Hz
Calibration: Issued with calibration certificate traceable to national
and international standards. 12 months typical
recalibration interval.
Warranty: 12 months parts and labour.
Servicing: Crane Electronics Ltd offer a full repair facility and
calibration to UKAS and international standards.
MAINS ADAPTOR POWER REQUIREMENTS
Standard Charge
Input: 230V AC 50 Hz 300mA (UK and Euro models)
Input: 115V AC 60 Hz 300mA (US models)
Output: 15V DC 800mA (all models)
Fast Charge
Input: 230V AC 50 Hz 700mA (UK and Euro models)
Input: 115V AC 60 Hz 700mA (US models)
Output: 12V DC >1A (all models)