Coke Factory Setup
Find Hook Swipe
This function enables the machine to run the vend mechanism to automatically find the hook swipe position.
Press button 4 and the vend mechanism will run to the delivery port to set the hook offset.
Coke Factory Setup
Mixed Credit
This function can be used to enable the consumer to use a combination of cash and card to make a purchase.
Press button 4 to view the current state. Press button 2 to change between ON and OFF. Press Key 1 to exit the
menu.
Test Modes
Test Vend Vend Testing:
This function allows you to test vend each column.
Press key number 4 and the display will show “Column A1”. Note: The left door switch must be pulled to the out
position to perform this test. Press key numbers 2 or 3 to scroll through the columns available to run in motor
test. Press and hold the Power Interrupt (PI) switch. Press key number 4 to vend from the column displayed. Press
key number 1 will return to “Test Vend”. Press key number 2 to scroll to next test mode.
Test Sel Switch Select Switch Test:
This function allows you to test each selection.
Press key number 4 and the display will show “Selection 4”. Then press any key and the display will show the last key
number pressed. Press and hold key number 1 for approximately 5 seconds will return to “Test Sel Switch”. Press key
number 2 to scroll to the next test mode.
Test Display Display Test:
This function allows you to test all segments in the display. Press key number 4 and a row of lower case letters
“a” through “t” will display, then turn off , then a row of upper case letters “A” through “T” will display alternating
until key number 1 has been pressed. Press key number 1 to return to “Test Display”. Press key number 2 to scroll
to next test mode.
Test Relays Relay Test:
This function allows you to test the relay electronic control of the compressor (“Compressor #”), the evaporator fan(s)
(“Fan #”), and the sign front light (“Light#”).
CAUTION: Disconnect power to the compressor before testing the compressor relay. Failure to disconnect power to the
compressor before testing the relay could result in damaging the compressor.
Press key number 4 and the display will show “Compressor #”, where # is the state of the relay - 0 = not activated
or off; 1 = activated or on. Press key number 4 to toggle the relay on and off. Press key number 2 to scroll to “Fan
#”, where # is the state of the relay - 0 = not activated or off, 1 = activated or on. Press key number 4 to toggle the
fan(s) on and off. Press key number 2 to scroll to “Light #”, where # is the state of the relay - 0 = not activated or
off; 1 = activated or on. Press key number 4 to toggle the lights on and off.
Press key number 1 to return to “Test Modes”.
Press key number 2 to scroll toReturn to Sales”.