- Page 17 -
2:2 How do I do to…?
2.2.1 See a non changeable register:
The non changeable registers are L03 and L04.
A. The display shows the state of the leveller, shelter or the door.
B. Press LEFT BUTTON SW1, menu [L] is showed. Enter Leveller submenu by RIGHT BUTTON
SW2 L01 is showed.
C. Press SW1 several times until submenu L03 is showed. Enter the submenu by RIGHT BUTTON
SW2, the display shows the total number of leveller cycles.
D. Press SW2 to exit back to submenu.
E. The display now shows L03. Use the LEFT BUTTON (SW1) to step to the next menu until the
display shows the menu of your choice (in this case L04, see Table 2).
F. Press the RIGHT BUTTON (SW2) to activate the chosen submenu L04.
G. The display will now show the total operating time (for example the value ”19”). This means that
the leveller has been powered 19 days and nights (456h). The value shown is continuously
updated.
H. Press the RIGHT BUTTON (SW2) to exit back to the submenu.
I. Press LEFT BUTTON (SW1) several times until the display shows [L], press three more time on
SW1 to exit from service menu.
Alternatively press LEFT BUTTON SW1 continuously for 2sec. to exit from service menu.
J. The display now goes back to normal operation showing the state of the leveller, shelter or the
door.
2.2.2 Set the limits for service interval:
A. The display shows the state of the leveller, shelter or the door.
B. Press LEFT BUTTON SW1, menu [L] is showed. Enter Leveller submenu by RIGHT BUTTON
SW2 L01 is showed.
C. Press SW1 several times until submenu L06 or L07 (see Table 1) is showed. Enter for example
the submenu L06 by RIGHT BUTTON SW2, the display now shows the value for the previous
setting, for example ”190”, meaning 190 000 cycles.
D. Press the LEFT BUTTON (SW1) to increase the value for the service interval in number of
leveller cycles (x1000). The value shown will now increase by 1 (1000 cycles). If the button is
pressed a little while, the fast stepping function activates. When the value goes above 999 it starts
over at 0.
E. To leave the menu without saving the new value press SW2. To leave the menu and save the
value, keep RIGHT BUTTON (SW2) pressed while pressing LEFT BUTTON (SW1).
F. Press LEFT BUTTON (SW1) several times until the display shows [L], press three more time on
SW1 to exit from service menu.
Alternatively press LEFT BUTTON SW1 continuously for 2sec. to exit from service menu.
G. The display now goes back to normal operation showing the state of the leveller, shelter or the
door.
2.2.3 Reset the operating time counter:
A. The display shows the state of the leveller, shelter or the door.
B. Press LEFT BUTTON SW1, menu [L] is showed. Enter Leveller submenu by RIGHT BUTTON
SW2 L01 is showed.
C. Press SW1 several times until submenu L05 is showed. Enter the submenu by RIGHT BUTTON
SW2. The display now shows the operating time in days that is stored in the internal memory, for
example 23 which means 23 days and nights.
D. Press the LEFT BUTTON (SW1) to reset the operating time counter. The previous value shown