87
ENGLISH
Working pressure
Calibration pressure (200 bar feeding)
Average inhalation effort (*)
Average exhalation effort (*)
Average breathing effort (*)
Air supply
Weight without hose
INT: 0÷230 bar - (0÷3365 psi); DIN: 0÷300 bar (0÷4350 psi)
10 bar (AC2) - (145 psi)
10 mbar
13 mbar
1,4 J/l
1050 l/min.
200 gr
XS2 2nd stage
(*) Values measured in compliance with EN 250:2014 standard.
Working pressure
Calibration pressure (200 bar feeding)
Average inhalation effort (*)
Average exhalation effort (*)
Average breathing effort (*)
Air supply
Weight without hose
0÷230 bar (INT); 0÷300 bar (DIN)
10 bar (MC9 - MC5 - AC2)
6 mbar
10 mbar
1,1 J/l
1600 l/min.
135 gr
XS Compact Pro / XS Compact 2nd Stage
(*) Values measured in compliance with EN 250:2014 standard.
2.10 - Performance
Working pressure
Calibration pressure (200 bar feeding)
Average inhalation effort (*)
Average exhalation effort (*)
Average breathing effort (*)
Air supply
Weight without hose
INT: 0÷230 bar - (0÷3365 psi); DIN: 0÷300 bar (0÷4350 psi)
10 bar (MC5) - (145 psi)
5,5 mbar
11 mbar
1,1 J/l
1800 l/min.
160 gr
Ellipse black 2nd stage
(*) Values measured in compliance with EN 250:2014 standard.