4. Wait 30 seconds, then insert the CR2450 battery, taking care to
position the new one the same way, with the positive pole facing
outward without reclosing the cap.
5. Wait 10 seconds.
6. Replace the battery compartment closing cap.
When this operation is complete, the DIGI console will run the
instrument seal test, which lasts a few minutes.
8. FAIL. The test was negative; the battery change must be
repeated because the instrument is not protected against
flooding. REPEAT THE STEPS TO CHANGE THE BATTERY
When the test concludes, the DIGI console will provide a response
regarding the battery change that was just performed:
7. PASS. The test was positive; the battery change was effective.