EasyManua.ls Logo

Cressi Michelangelo - Maintenance and Warranty; Computer Care and Battery Replacement

Cressi Michelangelo
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
35
English
USE OF THE COMPUTER WITH POOR VISIBILITY
Ifatany time during the divepoorlightconditionsmake it difcult to readthe
display,thedivercanturnonthebacklightfunctionbypressingtheLIGHTbutton.
Thedisplay’sbacklightlastsforafewseconds,andthenautomaticallyswitchesoff.
Whenthebacklightisonsomedarkpatchesmayalsoappearonthedisplay.The
patchesarenotadefect.Theyarecausedbytheuseofahigh-contrastdisplay.
SURFACE INTERVAL
AfteradiveinAIRMODEorNITROXMODE,whenyoureachdepthsshallowerthan
4ft./0.8m,thedisplayprovidesthefollowinginformation:
•Surfaceintervalgiveninhoursandminutes(SURF.T).
• Desaturation time (DESAT) to be respected before embarking on a ight (in
hoursandminutes).
• NoFlytimeandthecorrespondingicon.Whenthisiconisvisiblediversmust
avoid air travel and travel to altitudes higher than the dive location.
•Maxdepthreachedinthelatestdive.
•Durationofthelatestdive.
WARNING: In accordance with the instructions provided by the major
organizations that study diving and hyperbaric medicine, DONATELLO/
MICHELANGELO/RAFFAELLO applies the no-y time as follows: 12 hours
after a single dive without decompression. 24 hours after a dive with
decompressionorafterrepetitiveormultidaydives,ifcorrectlyperformed.24
or48hoursaftertheuseoftheGAGEfunction,orifseveremistakesindive
management occurred.
NOTE:Shouldadivebeginwithlessthan2minutesofsurfaceintervaltime,
DONATELLO/MICHELANGELO/RAFFAELLOwillconsiderthisacontinuationof
thepreviousdive;thedivenumberremainsthesame,anddivetimecalculation
willpickupfromwhereitleftoff.Divesexecutedafteratleast2minutesof
surfaceintervalareconsideredanewdive.IfadiveistakenusingtheGAGE
function,thedevicecannotcalculatesaturationordesaturationforthe48hours
followingtheendofthedive,representedbythesurfaceintervalSURF.T.
CARE AND MAINTENANCE
DONATELLO/MICHELANGELO/RAFFAELLO by Cressi has been designed to
operateinextremeconditionswithextensiveunderwateruse.Youshouldremember
thatitisaprecisioninstrumentdeservingappropriatecare.Pleaseavoidanyviolent
shocks,protectitfromextremeheatsources,alwaysrinseitwithfreshwaterafter
use,dryitcarefully,donotstoreitwet,andavoidcontactwithheavyequipment,
likedivingcylinders.
WARNING:Avoidcontactbetweenthecomputerandsolventsorchemical
substances. Do not use compressed air to dry the computer. The button does
notneedanyparticularmaintenance;nevergreaseitwithoilorspraysofany
kind.
NOTE: When replacing the battery, check its housing; should any signs of
moisture be visible, please have the instrument checked by an authorized
servicecenter.Shouldyounoticeanyanomalyinitsoperation,donotusethe
instrumenttodiveandhaveitcheckedbyanauthorizedCressiretailer.