Consumables Parts and Spare Parts
43 / 55
Tail clamp adjust failed.
Please clean air slot on drum or Contact engineer
Tail clamp position is over limit, please check.
Please clean air slot on drum or Contact engineer
Plate size is over limit (drum cannot be balanced!).
Please clean balance block sensor or Contact engineer
Vacuum pressure is not correct.
Tail clamp failed, please turn off and check.
Please clean air slot on drum or Contact engineer
Main board control process start failed.
Restart CTP and PC or Contact engineer
Autoloader control process start failed.
Restart autoloader or Contact engineer
Plate loading last time abnormal!
Open laser adjust program or Contact engineer
Cannot connect to autoloader.
Check power supply and cable connection
Check if plate on drum or do #105 test command or contact
engineer
Cannot connect to device! Make sure device is
power on and USB cable is connected or contact
engineer!
Check power supply, USB connection and USB drive.
Cannot read parameter file information!
Check if parameter file is correct
Device ID validate failed.
Read device ID again or contact engineer
Temperature compensation is not completed
(overtime)!
Check platform focus compensation movement or contact
engineer.
Main control board data flow is abnormal.
Restart PC or Contact engineer
When start record process, data in main control
board memory is not ready!
Restart PC or Contact engineer
Cannot start record process, platform position limit
signal is not correct.
Check platform position limit sensor or Contact engineer
Cannot find this error code information.
Check if dongle is plugged in
File size ## * ## is over template setting, cannot
open this file.
Setup another template or adjust current one
Resolution is not same, as template setting, cannot
open this file!
Setup another template or adjust current one
Check parameter or Contact engineer
Software version is too old, cannot read parameter!
Please update software.