EasyManua.ls Logo

Croplands WEED-IT Quadro - User Manual

Default Icon
123 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
HT-OMMICRO-A
1
WWW.CROPLANDS.COM.AU
BT-UMWEEDQ-C
USER MANUAL V4.16
WEED-IT
QUADRO
USER MANUAL

Table of Contents

Other manuals for Croplands WEED-IT Quadro

Question and Answer IconNeed help?

Do you have a question about the Croplands WEED-IT Quadro and is the answer not in the manual?

Summary

About this manual

Conventions

Defines bold and monospace type usage in the manual.

Icons

Explains the meaning of warning and information icons used in the manual.

About WEED-IT

Operating Principle

Explains how the WEED-IT system detects and sprays weeds using chlorophyll fluorescence.

Important Safety Information

General Safety Information

Covers safety icons, warnings, and general practices for safe operation.

Safety and Use of WEED-IT

Outlines responsibilities and authorized use of the WEED-IT system.

General Safety Instructions and Accident Prevention

Provides basic safety rules and advice for avoiding accidents.

Safety - Electrical Installation

Specific safety precautions related to the electrical system, fuses, and battery connections.

Sensor Operation Safety

Warns about the intense light from sensors and potential eye damage.

Crop Protection Solutions Safety

Safety guidelines for using crop protection products and handling the machine.

Intended Use

Defines the proper application of the WEED-IT system as an add-on to crop spraying.

Warnings for Crop Protection Products

Highlights potential damages from specific product types and cleaning recommendations.

Switching On and Off

Details the procedure for turning the WEED-IT system on and off.

Forced Shutdown

Explains how to perform a forced shutdown in case of system failure.

Before Each Use

Identification of Parts

System Overview

Lists the main electronic components and additional required parts for the WEED-IT system.

User Console

On;Off Switch

Details the location and operation of the power switch on the user console.

Display Overview

Explains the content of the start-up and main screens, showing system status and data.

Function Keys

Explains the purpose and usage of the five function keys on the user console.

Navigation Keys

Describes the use of arrow keys and the menu key for navigating the system interface.

Using WEED-IT

Main Menu and Service Mode

Differentiates between the default Main menu and the Service mode for system settings.

Pressure Check

Details the procedure for checking system pressure before each use.

Sensors Check

Outlines the steps to verify the functionality of the detection sensors.

Cleaning Nozzles

Provides methods for flushing and cleaning all or individual nozzles to prevent clogging.

Reading Job Productivity

Explains how to check job productivity data available on the main screen.

Changing Spray Settings

Guides on selecting different spray modes like Spot plain, Full coverage, etc.

Changing Spray Margin

Explains how to adjust the spraying margin during operation, e.g., for wind compensation.

Changing Sensitivity

Details how to adjust sensor sensitivity using presets for different environmental conditions.

Machine on Hold

Describes how to temporarily stop spraying using the Hold function, e.g., for turning on headlands.

General Maintenance

Safety - Electrical Installation

Specific safety precautions related to the electrical system, fuses, and battery connections.

Sensor Maintenance

Covers regular cleaning of sensor windows and troubleshooting leaky sensors.

Nozzle and Solenoid Valve Maintenance

Recommends filters, rinsing procedures, and steps for replacing nozzles.

Cleaning, Storage and Transport

General Storage Instructions

Provides guidelines for storing the machine in a dry, warm place and disconnecting the battery.

User Console Reference

Main Menu

Describes the default mode and how to navigate through menus from the main screen.

Main Menu Options

Lists the options available for regular use of the WEED-IT system from the main menu.

Preset Menu Options

Explains how to change spraying margin and sensor sensitivity using presets.

Service Mode

Details how to enter Service mode and lists the available sub-menus like Information, Warnings, etc.

Information Menu (100)

Provides general system information and data for each sensor.

Warnings Menu (101)

Explains how warnings are displayed and stored, and how to clear them.

Nozzle Cleaning Menu (102)

Describes functions for flushing nozzles, testing detection, and solenoid valves.

Job Menu (103)

Allows viewing recorded data of the current job, including time, area, dose, liquid, usage, and savings.

PWM;Nozzle Selection Menu (104)

Guides on selecting spray mode, nozzle type, pressure, and ideal speed.

Spray Modes

Full Coverage Mode

Sprays liquid continuously, setting the application rate for the entire field.

Dual Function

Combines spot spraying and full coverage, applying different rates for weeds and the field.

Plain Green on Green (Optional)

A spray mode similar to Spot plain, but utilizes different sensitivity presets.

Spot Green on Green (Optional)

A spray mode similar to Spot spraying, but utilizes different sensitivity presets.

User Settings Menu

Configuration (150)

Allows setting display language, alarm volume, and contrast.

Units (151)

Enables selection of units for speed, distance, fluid, and pressure.

Options (152)

Options for history per job, Imperial Units, and US date notation.

Set Time;Date (153)

Procedure for setting the internal clock and date, especially after battery replacement.

Troubleshooting

Messages

Explains how WEED-IT identifies and displays errors, warnings, and messages.

Warnings and Errors Overview

Lists common errors/warnings and provides methods for resolution.

Specifications

WEED-IT Quadro Sensor Specifications

Details electronic and housing/mounting specifications for the sensors.

Sensor Detection and Solenoid Control Specifications

Lists technical details for sensor detection and solenoid valve operation.

WEED-IT Quadro Solenoid Valve Specifications

Details valve type, compatibility, voltage, resistance, and filtering requirements.

WEED-IT Quadro Power Converter (PSU) Specifications

Provides technical specifications for different PSU models, including sensor capacity and power ratings.

WEED-IT Quadro User Console Specifications

Lists technical specifications for the user console, including voltage, power, and dimensions.

Menu Options Overview

Service Mode

Illustrates the flow and available sub-menus within the Service mode.

WEED-IT Software Information

Calibration Settings Form

General Machine Information

A form for dealers to record system settings during setup and testing.

Dealer Menu Configuration Settings

Section for configuring dealer-specific settings, starting with console and sensor info.

Menu 200 Console and Sensor Information

Details for recording console serial numbers and individual sensor serial numbers.

Menu 203 Configuration

Configuration settings for Speed and Flow parameters, including units and roles.

Menu 205 Sensor Settings

Settings for sensor position, margin, track, and fluid configuration.

Menu 206 Sensor Setup

Configuration for nozzle height (h) and distance (d) from the detection line.

Menu 213 Margin Presets

Settings for predefined spraying margins, applicable when user/wind margin is enabled.

Menu 216 Height Sensors

Configuration for height sensors, including nominal values and clearances.

Other Information

Other Manuals

Lists related technical documents such as ISOBUS user manual and Parts List.

Available Nozzles

Provides a comprehensive list of compatible nozzles with their specifications and recommended spray modes.

Nozzle Flow Rate Charts

Contains charts detailing application rate ranges for various nozzles based on pressure, speed, and height.

Application Rate Calculations

Explains the formulas and calculations for determining application rates in Spot Spraying mode.

Full Coverage Spraying Formulas

Provides the calculation formulas for application rates in Full Coverage mode.

Dual Spraying Formulas

Explains the calculation formulas for the Dual Spraying mode, combining spot and cover rates.

Croplands WEED-IT Quadro Specifications

General IconGeneral
Sensor TypeOptical sensors
TypeWeed detection and spraying system
TechnologyOptical Detection
ApplicationAgricultural weed management
CompatibilityCompatible with various sprayer models
Working WidthVaries depending on boom configuration
Tank CapacityVaries by Model
Power Requirement12V DC