EasyManua.ls Logo

Crown 2/300 User Manual

Crown 2/300
91 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Product Registration: Register your new product at www.warranty.harmanpro.com.
Obtaining Other Language Versions: To obtain information in another language about the use of this product, please contact your local Crown
Distributor. If you need assistance locating your local distributor, please contact Crown at 574-294-8000 or visit www.crownaudio.com.
This manual does not include all of the details of design, production, or variations of the equipment. Nor does it cover every possible situation which may
arise during installation, operation, or maintenance.
The information provided in this manual was deemed accurate as of the publication date. However, updates to this information may have occurred. To
obtain the latest version of this manual, please visit the Crown website at www.crownaudio.com.
Trademark Notice: Com-Tech, BCA, Crown, Crown Audio, Amcron and Multi-Mode are registered trademarks of Crown International. DriveCore,
DriveCore Install, IQwic, PIP and PIP2 are trademarks of Crown International. Other trademarks are the property of their respective owners.
Some models may be exported under the name Amcron
®
© 2016 by HARMAN International
®
, Inc. 1718 W. Mishawaka Rd., Elkhart, Indiana 46517-9439 U.S.A. Telephone: 574-294-8000
CDi DriveCore Series
Power Amplifiers
Operation Manual
5074176-A – 11/16
SERIAL NUMBERSERIAL NUMBER
BAR CODE
100-240V
~ 50/60Hz 350W
1718 W. MISHAWAKA
RD.
CAUTION - TO REDU CE THE RISK OF EL ECTRIC
SHOCK, GROUNDING OF T HE CENTER PIN
OF THIS P LUG MUST BE MAINTAIN ED
ATTENTION - POUR RÉDUIRE L E RISQUE DE CHO C
ÉLECTRIQUE LA FICHE CENTRALE LA PRISE DOIT Ê TRE
BRANCHÉE P OUR MAINT ENIR LA MISE À L A TERRE
WARNING
-
TO REDUCE THE RISK
OF FIRE OF ELECTRICAL SHOCK, DO
NOT EXPOSE THIS EQUIPMENT TO RAIN
OR MOISTURE.
AVERTISSEMENT
- ENERGIE
ELECTRIQUE DANGEREUSE` VOIR LE
CAHIER D’INSTRUCTIONS.
APPARATET MA TILKOPLES JORDET
STIKKONTAKT.
APPARATEN SKALL ANSLUTAS TILL
JORDAT UTTAG.
LAITE ON LIITETTÄVÄ
SUOJAKOSKETTIMILLA VARUSTETTUUN
PISTORASIAAN.
RISK OF ELECTRIC
SHOCK
AVERTISSEMENT: RISQUE DE CHOC
ELECTRIQUE - NE PAS OUVRIR
CLASS 2 OUTPUT WIRING PERMITTED.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING CONDITIONS.
1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE.
2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE THAT
MAY CAUSE UNDESIRED OPERATION.
WARNING
OUTPUTOUTPUT INPUT
2 14 3
2 1
DUALDUAL
BRIDGE
OUTPUT
WIRING
ETHERNET
100Mb
ACT
GPIO/AUX
BLU linkIN OUT
OUT
12
IN
3
AMP STATUS
7
+3.3V
45
IN
6
SLEEP
8
SERIAL NUMBERSERIAL NUMBER
BAR CODE
100-240V
~ 50/60Hz 350W
1718 W. MISHAWAKA RD.
ELKHART IN 46517 USA
CAUTION - TO REDU CE THE RISK OF EL ECTRIC
SHOCK, GROUNDING OF T HE CENTER PIN
OF THIS P LUG MUST BE MAINTAIN ED
ATTENTION - POUR RÉDUIRE L E RISQUE DE CHO C
ÉLECTRIQUE LA FICHE CENTRALE LA PRISE DOIT Ê TRE
BRANCHÉE P OUR MAINT ENIR LA MISE À L A TERRE
WARNING
-
TO REDUCE THE RISK
OF FIRE OF ELECTRICAL SHOCK, DO
NOT EXPOSE THIS EQUIPMENT TO RAIN
OR MOISTURE.
AVERTISSEMENT
- ENERGIE
ELECTRIQUE DANGEREUSE` VOIR LE
CAHIER D’INSTRUCTIONS.
APPARATET MA TILKOPLES JORDET
STIKKONTAKT.
APPARATEN SKALL ANSLUTAS TILL
JORDAT UTTAG.
LAITE ON LIITETTÄVÄ
SUOJAKOSKETTIMILLA VARUSTETTUUN
PISTORASIAAN.
RISK OF ELECTRIC
SHOCK
AVERTISSEMENT: RISQUE DE CHOC
ELECTRIQUE - NE PAS OUVRIR
CLASS 2 OUTPUT WIRING PERMITTED.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING CONDITIONS.
1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE.
2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE THAT
MAY CAUSE UNDESIRED OPERATION.
WARNING
OUTPUTOUTPUT INPUT
2 14 3
2 1
DUALDUAL
BRIDGE
OUTPUT
WIRING
ETHERNET
100Mb
ACT
GPIO/AUX
BLU linkIN OUT
OUT
12
IN
3
AMP STATUS
7
+3.3V
45
IN
6
SLEEP
8
2|300
2|300BL
2|600
2|600BL
4|300
4|300BL

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Crown 2/300 and is the answer not in the manual?

Crown 2/300 Specifications

General IconGeneral
Channels2
8 Ohm Bridged Mono Power900W
4 Ohm Stereo Power450W
Input Impedance20kΩ balanced, 10kΩ unbalanced
Dimensions19"
Weight25 lb
8 Ohm Stereo Power300W per channel

Summary

Welcome

Features

Key features and technologies of the CDi DriveCore Series amplifiers.

How to Use this Manual

Guidance on navigating and utilizing the operation manual effectively.

Installing the Amplifier

Unpacking and Initial Inspection

Procedures for unpacking the amplifier and checking for transit damage.

Additional Materials and Proper Cooling

Lists required installation materials and guidelines for adequate amplifier cooling.

Front Panel Overview

Front Panel Components Description

Detailed explanation of the front panel's controls, indicators, and display elements.

Rear Panel Overview

Rear Panel Connectivity Ports

Description of all rear panel connectors for audio, network, and control interfaces.

Hardware Setup Procedures

AC Power Connection and Power-Up

Steps for connecting AC power and performing the initial amplifier power-up sequence.

Precautions

Safety and Operational Precautions

Essential safety guidelines and precautions for amplifier operation and setup.

Wiring Procedures

Wiring Input Connectors

Instructions for connecting audio sources to the amplifier inputs.

Wiring Output Connectors

Guidelines for connecting loudspeakers to the amplifier outputs.

Front Panel Menus and Navigation

Menu Structure Overview

Visual representation of the amplifier's front panel menu hierarchy.

Adjusting Channel Volume

Methods for adjusting system-wide and individual channel volume levels.

The Home Screen

Home Screen Layout and Navigation

Explanation of the default home screen display and available navigation options.

Configuring the Amplifier

Guided Setup Procedure

Step-by-step guide for initial amplifier configuration using the front panel wizard.

Input and Output Configuration

Steps for assigning input sources and configuring output channels.

Amp Wiring and Bridge Mode

How to configure input wiring and bridge mono operation for output pairs.

Assigning Input Sources

Process for selecting and assigning audio sources to amplifier inputs.

BLU link Settings

Configuration options for BLU link digital audio transport, including sample rate and priority.

Output Mode Configuration

Setting output impedance modes (Low Z, 70V, 100V) for different speaker configurations.

DSP Configuration

Manual adjustment of digital signal processing modules like delay, EQ, and crossover.

Delay Settings

Configuring input and output delay times for driver alignment and system timing.

Crossover Filter Settings

Editing crossover filter types, frequencies, and slopes for speaker frequency management.

Parametric EQ (PEQ) Configuration

Adjusting input and output equalization using parametric EQ bands.

Limiter Settings

Configuring peak, RMS, and thermal limiters to protect drivers and the amplifier.

Audio Architect and Network Setup

Introduction to HiQnet Audio Architect

Overview of using Audio Architect software for amplifier configuration and control.

Network Configuration Settings

Steps for configuring amplifier network settings via front panel or software.

Using NetSetter Software

Utilizing NetSetter for discovering and configuring HiQnet devices on the network.

Using HiQnet Audio Architect

Offline and Online Operation Modes

Understanding the differences between offline and online operation in Audio Architect.

Matching Devices in Audio Architect

Associating discovered hardware devices with their virtual representations in Audio Architect.

Main Control Panel Overview

Exploring the functions and controls of the main amplifier control panel in Audio Architect.

Amplifier Information Panel

Accessing and configuring amplifier details like firmware, temperature, and panel lockout.

Configuring Inputs/Outputs in Audio Architect

Assigning input sources and configuring output routing within Audio Architect.

BLU link Clock and Output Configuration

Setting BLU link clock parameters and routing audio signals to BLU link outputs.

Amp Wiring and Output Modes in Audio Architect

Configuring amp wiring, bridge mode, and output impedance via Audio Architect.

Crossover and EQ Panels

Adjusting crossover filters and input/output equalization settings using Audio Architect.

Delay and LevelMAX Panels

Configuring delay times and LevelMAX limiter settings within Audio Architect.

Signal Generator Panel

Using the signal generator for tuning, troubleshooting, and testing loudspeakers.

Managing Device and Preset Files

Backing up and loading amplifier presets and device configurations.

Application Examples

Dual Mode, Low Z Configuration

Wiring and setup example for dual-mode operation with low impedance speakers.

Bridge Mono Mode, Low Z Configuration

Wiring and setup example for bridge-mono operation with low impedance speakers.

Dual Mode, High Z Configuration

Wiring and setup example for dual-mode operation with high impedance speakers.

Bridge Mono Mode, High Z Configuration

Wiring and setup example for bridge-mono operation with high impedance speakers.

Using BLU link

BLU link Specifications and Latency

Details on BLU link digital audio bus capabilities, channel count, and latency.

Making BLU link Connections

Instructions for physically connecting BLU link devices in a network loop.

BLU link Port LED Indicators

Interpreting the LED indicators on BLU link ports for status and connectivity.

Mastership and Fault Tolerance

Understanding BLU link bus mastership negotiation and fault tolerance mechanisms.

BLU link Status Menu

Viewing current BLU link sample rate, priority, and connection status.

Device Presets

Saving Device Presets

Procedures for saving amplifier configurations as user presets from the front panel.

Loading Device Presets

Steps for recalling saved device presets onto the amplifier.

System Settings

Lighting and Display Options

Configuring front panel LCD sleep timers and data light behavior.

Security and Front Panel Lockout

Enabling front panel lockout to prevent unauthorized access and tampering.

Amplifier Diagnostics

Accessing diagnostic information such as firmware, voltage, and temperature readings.

Amplifier Gain Mode

Setting the amplifier's input sensitivity and gain mode.

GPIO Control Port Usage

GPIO Pinout and Configuration

Detailed pinout and functional description of the GPIO control port.

AUX Port Usage

Sleep and Amp Status Monitoring

Using the AUX port for remote standby (sleep) and amplifier status monitoring.

System Protection

Possible Faults and Descriptions

Listing and explaining amplifier fault conditions and their causes.

Thermal Limit and High-Pass Filters

Information on thermal protection limits and auto-insertion of high-pass filters.

AC Protection and Fan Cooling

Details on AC voltage protection and fan cooling behavior under fault conditions.

Troubleshooting Common Issues

Power and Display Issues

Resolving problems related to the power indicator and front panel display.

Power Button and Sleep Issues

Troubleshooting amplifier not turning on or responding to the power button.

Thermal and Fault Error Indicators

Diagnosing and resolving thermal faults and general fault error messages.

Sound and Signal Issues

Identifying and fixing problems related to distorted sound, no sound, or no input signal.

Signal Path Block Diagram

Factory Reset Procedure

Specifications

Output Power Ratings

Table detailing output power for different models and impedance loads.

Input Sensitivity Settings

Table showing input sensitivity values for various gain modes and models.

Performance Specifications

Dimensions

Warranty Information (US Only)

Warranty Summary and Exclusions

Overview of the warranty period, coverage, and items excluded from warranty.

Obtaining Warranty Service

Instructions on how to contact Crown for warranty service and obtain authorization.

Service and Support

Obtaining Service (Worldwide & US/Canada)

Procedures for obtaining service through authorized centers or factory repair.

Factory Service Shipping Instructions

Guidelines for packing and shipping products for factory service.

Open Source Software Disclaimer

Open Source Licenses and Copyright Notices

List of open source libraries used and their associated licenses and copyright information.

GNU General Public License Version 2

GNU General Public License Version 3

Related product manuals